IQ Load Controller Manual
Tech Brief – Bill of Materials to Use Load Control 
2 © 2021 Enphase Energy Inc. All rights reserved.        May 21, 2021 
Bill of Materials to Use Load Control  
USING THIS DOCUMENT 
This document shows 3 of the options for the Ensemble Contactor Box that can be used to shed PV 
Circuits or Home Loads.  
BEST PRACTICES: Before going to the job site complete these steps from the office 
•  To ensure a consistent installation process and predictable installations times, make sure to 
ensemble the system contactor box at the warehouse, before going to the job site. 
•  Have sufficient inventory to build enough boxes for several projects at a time. 
•  Bring spare parts to the job site, including Fuses, Contactors and Transformers. 
•  Time to Assemble and install the Box on Site: 1hr.  
•  Time to install the Pre-Assemble Box on site: 30 min 
Load Control Type 
Bill of Materials 
Item 
Qty 
Description 
Excess Solar or Load 
Shedding for (1) 20A 
Circuit 
Control transformer 
1 
Endurance Pro EP4031OF 24V 40VA 
Fuse Retainer 
1 
Bussmann BP/HMK-RP fuse holder 
Fuse 
1 
NTC 74-6SG1A-C 1A 250V glass fuse 
Contactor 
1 
Eaton C25BNB220T 20A 
Box 
1 
Gratury Junction Box, Hinged Cover Stainless Steel Clip IP67 
Waterproof Plastic Enclosure for Electrical Project Includes 
Mounting Plate and Wall Bracket 290×190×140mm 
(11.4"×7.5"×5.5")  
Quick Disconnects/Fast 
on Terminals/Receptacle 
lug (required for 
contactors without screw 
on terminals) 
1 
PIDG, Quick Disconnects, Receptacle, 22 – 18AWG Wire Size 
TE Internal #: 640911-1 
Excess Solar or load 
Shedding for (2) 30A 
Circuit 
Control transformer 
1 
Fiada B07RDBS6NK 
Fuse Retainer 
2 
Eaton BP/HMK-RP fuse holder 
Fuse 
2 
Eaton BP-AGC-1-RP 250 V glass fuse 
Contactor 
2 
Square D 8910DP32V14 30A 
Box 
1 
Gratury Junction Box, Hinged Cover Stainless Steel Clip IP67 
Waterproof Plastic Enclosure for Electrical Project Includes 
Mounting Plate and Wall Bracket 290×190×140mm 
(11.4"×7.5"×5.5") 
Quick Disconnects/Fast 
on Terminals/Receptacle 
lug (required for 
contactors without 
screw-on terminals) 
1 
PIDG, Quick Disconnects, Receptacle, 22 – 18AWG Wire Size 
TE Internal #: 640911-1 
Excess Solar or Load 
Shedding for (1) 60A 
Circuit 
Control transformer 
1 
Fiada B07RDBS6NK 
Fuse Retainer 
1 
Littelfuse Universal Fuse Retainer Part No: 150145 
Fuse 
1 
NTC 74-6SG1A-C 1 A 250V glass fuse 
Contactor 
1 
Square D 8910DPA63V14 60 A 
Box 
1 
6X6 PVC box rated for outdoor use (NEMA 3R or better) (Carlon 
junction box, for example) 



