Datasheet

To learn more about Enphase offerings, visit enphase.com
© 2019 Enphase Energy. All rights reserved. Enphase, the Enphase logo, Enpower, and other trademarks or service names are the trademarks of Enphase
Energy, Inc. Data subject to change.
2019-12-11
MODEL NUMBER
EP200G101-M240US00 Enphase Enpower smart switch with neutral-forming transformer (NFT), Microgrid
Interconnect Device (MID), breakers, and screws. Streamlines grid-independent capabilities
of PV and storage installations.
ACCESSORIES and REPLACEMENT PARTS
XA-E3-PCBA-ENS Replacement Enpower controller printed circuit board
Circuit Breakers (as needed)¹
BRK-100A-2P-240V
BRK-125A-2P-240V
BRK-150A-2P-240V
BRK-175A-2P-240V
BRK-200A-2P-240V
BRK-20A-2P-240V
BRK-30A-2P-240V
BRK-40A-2P-240V
BRK-60A-2P-240V
BRK-80A-2P-240V
Not included, must be ordered separately:
Main breaker, 2 pole, 100A, 25kAIC, CSR2100N
Main breaker, 2 pole, 125A, 25kAIC, CSR2125N
Main breaker, 2 pole, 150A, 25kAIC, CSR2150N
Main breaker, 2 pole, 175A, 25kAIC, CSR2175N
Main breaker, 2 pole, 200A, 25kAIC, CSR2200N
Circuit breaker, 2 pole, 20A, 10kAIC, BR220B
Circuit breaker, 2 pole, 30A, 10kAIC, BR230B
Circuit breaker, 2 pole, 40A, 10kAIC, BR240B
Circuit breaker, 2 pole, 60A, 10kAIC, BR260
Circuit breaker, 2 pole, 80A, 10kAIC, BR280
ELECTRICAL SPECIFICATIONS
Assembly rating Continuous operation at 100% of its rating
System voltage 120/240 VAC, 60 Hz
Maximum continuous current rating 160 A
Maximum output overcurrent protection device 200 A
Maximum input overcurrent protection device 200A
Maximum overcurrent protection device rating for
storage branch circuit
2
80A
Maximum overcurrent protection device rating for PV
combiner branch circuit
2
80A
NFT Breaker rating (pre-installed) 40A between L1 and Neutral; 40A between L2 and Neutral
MECHANICAL DATA
Dimensions (WxHxD) 50cm x 91.6cm x 24.6cm (19.7 in x 36 in x 9.7 in)
Weight 37.2 kg (82 lbs)
Ambient temperature range -40º C to +50º C (-40º to 122º F)
Cooling Natural convection, plus heat shield
Enclosure environmental rating Outdoor, NEMA type 3R, polycarbonate construction
Wire sizes • Grid input : Up to AWG 4/0 Cu/Al conductors
• Load panel : Up to AWG 4/0 Cu/Al conductors
• Main load panel output : Up to AWG 4/0 Cu/Al conductors
• Generator input : Up to AWG 14 to AWG 6 Cu conductors
• Encharge input : Up to AWG 14 to AWG 6 Cu conductors
• PV Combiner input: Up to AWG 14 to AWG 6 Cu conductors
• Ground : Up to AWG 14 to AWG 1/0 Cu conductors
• Neutral : Up to AWG 14 to AWG 4/0 Cu conductors
Always follow local electrical code requirements for conductor sizing.
Altitude To 2500 meters (8200 feet)
COMPLIANCE
Compliance This product will comply with all the required regulatory certications in the North American
markets before launch. Details will be provided in the nal data sheet.
1. Compatible with BRHDK125 Hold-Down Kit to comply with 2017 NEC 710.15E for back-fed circuit breakers.
2. Not included. Installer must provide properly rated breaker per circuit breaker list above.
Enphase Enpower