MODEL NUMBER
EP200G101-M240US00 Enphase Enpower smart switch with neutral-forming transformer (NFT), Microgrid
Interconnect Device (MID), breakers, and screws. Streamlines grid-independent capabilities
of PV and storage installations.
ACCESSORIES and REPLACEMENT PARTS
XA-E3-PCBA-ENS Replacement Enpower controller printed circuit board
Circuit Breakers (as needed)¹
BRK-100A-2P-240V
BRK-125A-2P-240V
BRK-150A-2P-240V
BRK-175A-2P-240V
BRK-200A-2P-240V
BRK-20A-2P-240V
BRK-30A-2P-240V
BRK-40A-2P-240V
BRK-60A-2P-240V
BRK-80A-2P-240V
Not included, must be ordered separately:
• Main breaker, 2 pole, 100A, 25kAIC, CSR2100N
• Main breaker, 2 pole, 125A, 25kAIC, CSR2125N
• Main breaker, 2 pole, 150A, 25kAIC, CSR2150N
• Main breaker, 2 pole, 175A, 25kAIC, CSR2175N
• Main breaker, 2 pole, 200A, 25kAIC, CSR2200N
• Circuit breaker, 2 pole, 20A, 10kAIC, BR220B
• Circuit breaker, 2 pole, 30A, 10kAIC, BR230B
• Circuit breaker, 2 pole, 40A, 10kAIC, BR240B
• Circuit breaker, 2 pole, 60A, 10kAIC, BR260
• Circuit breaker, 2 pole, 80A, 10kAIC, BR280
ELECTRICAL SPECIFICATIONS
Assembly rating Continuous operation at 100% of its rating
System voltage 120/240 VAC, 60 Hz
Maximum continuous current rating 160 A
Maximum output overcurrent protection device 200 A
Maximum input overcurrent protection device 200A
Maximum overcurrent protection device rating for
storage branch circuit
2
80A
Maximum overcurrent protection device rating for PV
combiner branch circuit
2
80A
NFT Breaker rating (pre-installed) 40A between L1 and Neutral; 40A between L2 and Neutral
MECHANICAL DATA
Dimensions (WxHxD) 50cm x 91.6cm x 24.6cm (19.7 in x 36 in x 9.7 in)
Weight 37.2 kg (82 lbs)
Ambient temperature range -40º C to +50º C (-40º to 122º F)
Cooling Natural convection, plus heat shield
Enclosure environmental rating Outdoor, NEMA type 3R, polycarbonate construction
Wire sizes • Grid input : Up to AWG 4/0 Cu/Al conductors
• Load panel : Up to AWG 4/0 Cu/Al conductors
• Main load panel output : Up to AWG 4/0 Cu/Al conductors
• Generator input : Up to AWG 14 to AWG 6 Cu conductors
• Encharge input : Up to AWG 14 to AWG 6 Cu conductors
• PV Combiner input: Up to AWG 14 to AWG 6 Cu conductors
• Ground : Up to AWG 14 to AWG 1/0 Cu conductors
• Neutral : Up to AWG 14 to AWG 4/0 Cu conductors
Always follow local electrical code requirements for conductor sizing.
Altitude To 2500 meters (8200 feet)
COMPLIANCE
Compliance This product will comply with all the required regulatory certications in the North American
markets before launch. Details will be provided in the nal data sheet.
1. Compatible with BRHDK125 Hold-Down Kit to comply with 2017 NEC 710.15E for back-fed circuit breakers.
2. Not included. Installer must provide properly rated breaker per circuit breaker list above.