D. Insert a screwdriver into the slot on top of the terminator to hold it in place, and use a 27 mm
wrench or channel lock pliers to tighten the hex nut until the threads disappear.
E. Hold the terminator body stationary with the screwdriver and turn only the hex nut to prevent
the conductors from twisting out of the separator.
NOTE: Hold the terminator body stationary with the screw driver and turn only the hex
nut to prevent conductors from twisting out of the separator.
F. Attach the terminated cable end to the PV racking with a cable clip or tie wrap so that the
cable and terminator do not touch the roof.
WARNING: Never unscrew the hex nut. Unscrewing the hex nut destroys the locking
feature, and you must replace the terminator.