Using Enphase Field Wireable Q Connectors
Use Enphase Field connectors with Enphase Q-Cable or field cable to:
Easily connect Q Cables on the roof without complex wiring
Use male connectors to make connections from any Q Aggregator open connector
Use female connectors to make connections from any Q Cable open connector
Make a jumper to connect with a remote part of the array with any combination of connectors
Center-feed branch circuits to minimize voltage rise in a fully-populated branch
Use two opposite sex Field Wireable connectors to form splices
Enphase Items:
Field-Wireable Q Connector (Female): (Q-CONN-10F)
Field Wireable Q Connector (Male): (Q-CONN-10M)
Other Items:
Diagonal cutter
Wire stripper
Crimp tool: Multi-Contact PV-CZM-18100, -019100, or -22100
Channel lock pliers