16
Table 9: IQ8+ – Denver, -0.35%/°C simple eciency model, 180° azimuth, 20° tilt.
Module Power
(W)
DC:AC Ratio
Annual Energy
(kWh)
AC Capacity
Factor (%)
Year 1
Inverter
Clipping loss
(kWh)
Year 1
Inverter
Clipping loss
(%)
Total
Inverter
Clipping in 25
Years (%)
300 1.00 527.5 20.1 0.0 0.0 0.0
315 1.05 554.0 21.1 0.0 0.0 0.0
330 1.10 580.6 22.1 0.0 0.0 0.0
345 1.15 607.0 23.1 0.1 0.0 0.0
360 1.20 632.9 24.1 0.7 0.1 0.0
375 1.25 657.6 25.0 2.6 0.4 0.0
390 1.30 680.3 25.9 6.5 0.9 0.0
405 1.35 700.9 26.7 12.5 1.7 0.1
420 1.40 719.8 27.4 20.2 2.6 0.2
435 1.45 737.2 28.1 29.4 3.7 0.4
450 1.50 753.2 28.7 40.0 4.8 0.8
465 1.55 767.8 29.2 52.0 6.1 1.4
480 1.60 781.4 29.7 65.1 7.4 2.2
495 1.65 794.3 30.2 78.9 8.7 3.2
510 1.70 806.6 30.7 93.3 10.0 4.4
525 1.75 818.3 31.1 108.2 11.2 5.8
540 1.80 829.4 31.6 123.8 12.5 7.2
IQ8+ simulation results
The following tables shows the simulated single-module values for dierent DC:AC ratios on the IQ8+ Microinverter in
locations covering across the United States, using a -0.35%/C simple eciency model. The IQ8+ Microinverter has a peak
output power rating of 300 VA. In this model, the module orientation is xed at 180° azimuth, 20° tilt. Many real-world PV
systems do not have ideal true south orientations of 180° azimuth and ideal tilt angles, so the impact of clipping will be less
than shown in the tables below.