IQ8 PV Module Rating Larger Than Inverter Rating

© 2022 Enphase Energy, Inc. All rights reserved.
Enphase Energy®, the Enphase logo, Encharge, Enlighten, Enlighten Manager, Enpower, Ensemble, MyEnlighten, and other trademarks or service names are the trademarks
of Enphase Energy, Inc. Other names are for informational purposes and may be trademarks of their respective owners.
41
Table 34: IQ8H-240 – Los Angeles, -0.35%/°C simple eciency model, 180° azimuth, 20° tilt.
Module
Power (W)
DC:AC
Ratio
Energy Yield
(kWh/kW)
AC
Capacity
Factor (%)
Performance
Ratio
Year 1
Inverter
Clipping loss
(KWh)
Year 1
Inverter
Clipping loss
(%)
Total
Inverter
Clipping in 25
Years (%)
 . 1827.4 20.9 0.81 0.0 0.0 0.0%
 . 1827.8 22.0 0.81 0.0 0.0 0.0%
 . 1828.0 22.8 0.81 0.0 0.0 0.0%
 . 1828.2 23.9 0.81 0.0 0.0 0.0%
 . 1827.9 25.0 0.81 0.6 0.0 0.0%
 . 1823.9 26.0 0.81 4.7 0.3 0.0%
 . 1823.9 26.0 0.81 4.7 0.3 0.0%
 . 1797.0 27.8 0.80 30.6 1.7 0.1%
540 1.41 1776.4 28.5 0.79 49.8 2.8 0.2%
560 1.46 1753.2 29.2 0.78 70.9 4.0 0.5%
575 1.50 1734.0 29.6 0.77 87.8 5.1 0.9%
590 1.54 1706.2 30.2 0.76 111.7 6.5 1.6%
615 1.60 1677.4 30.7 0.75 135.5 8.1 2.7%
635 1.65 1648.4 31.1 0.73 158.6 9.6 4.1%
655 1.71 1620.0 31.5 0.72 180.3 11.1 5.7%
670 1.74 1599.3 31.9 0.71 195.7 12.2 6.9%
690 1.80 1572.1 32.2 0.70 215.0 13.7 8.5%