Product Manual

FIELD-WIREABLE CONNECTORS
Check that you have Enphase Field Wireable Q Connectors as needed for
your installation. Both female and male connectors are sold in packs of ten:
Field-Wireable Q connector (female): (Q-CONN-10F)
Field-Wireable Q connector (male): (Q-CONN-10M)
Make sure you have the following required tools:
Diagonal cutter
Wire stripper
Crimp tool: Multi-Contact PV-CZM-18100, -19100, or -22100
Channel lock pliers or torque wrench
Enphase disconnect tool
When to Use Field-Wireable Q Connectors
Use Enphase eld-wireable connectors with Enphase Q-Cable or eld
cable to:
Easily connect Q cables on the roof without complex wiring
Use male connectors to make connections from any Q Aggregator
open connector
Use female connectors to make connections from any Q Cable
open connector
Make a jumper to connect with a remote part of the array: Use
female to female for cable-to-cable connections, or male to female
for aggregator-to-cable extensions
Use a mated pair of connectors to splice two cut ends of cable
PREPARATION
Enphase
disconnect
tool
Safety Instructions
+
DANGER: Risk of electric shock. Do not use Enphase
equipment in a manner not specied by the manufacturer.
Doing so may cause death or injury to persons, or damage
to equipment.
+
DANGER: Risk of electric shock. Be aware that installation
of this equipment includes risk of electric shock. Do not use
without rst removing AC power from the Enphase System.
Disconnect the power coming from the photovoltaics
before servicing or installing.
+
DANGER: Risk of electric shock. Risk of re. Before making
any connections verify that the circuit breakers are in the off
position. Double check all wiring before applying power.
+
DANGER: Risk of electric shock. Risk of re. Only use
electrical system components approved for wet locations,
including but not limited to conduit ttings.
+
DANGER: Risk of electric shock. Risk of re. Only qualied
personnel should install, troubleshoot, or replace the
Enphase Field Wireable Connector.
+
DANGER: Risk of electric shock. Improper use of the Field
Wireable Connector or its components may result in a
shock, re or explosion. To reduce these risks, disconnect
all wiring before attempting any maintenance.
+
DANGER: Risk of electric shock. Risk of re. Ensure that all
AC and DC wiring is correct and that none of the AC wires
are pinched, shorted, or damaged.
+
DANGER: Risk of electric shock. Risk of re. Do not attempt
to repair or alter the Enphase Field Wireable Connector.
+
DANGER: Risk of electric shock. Risk of re. Make sure
the conductors are not damaged. If the exposed wires are
damaged, the system may not function properly.
*
WARNING: Risk of equipment damage. Enphase male and
female connectors must only be mated with the matching
male/female connector.
Safety Symbols
+
DANGER: This indicates a hazardous situation, which if not
avoided, will result in death or serious injury.
*
WARNING: This indicates a situation where failure to
follow instructions may be a safety hazard or cause
equipment malfunction. Use extreme caution and follow
instructions carefully.
;
WARNING: Risk of burn. Failure to follow instructions may
result in burn injury.
NOTE: This indicates information particularly important for
optimal system operation.
SAFETY
IMPORTANT SAFETY INSTRUCTIONS.
SAVE THIS INFORMATION.
Follow all safety and assembly instructions when installing
Enphase Field Wireable Connectors.
Safety Instructions
*
WARNING: Risk of equipment damage. This product is
intended for operation in an environment having a maximum
ambient temperature of 55ºC (131ºF).
*
WARNING: When installing the cabling, secure any loose
cable to minimize tripping hazard
*
WARNING: Before installing or using the Enphase Field
Wireable Connector, read all instructions and cautionary
markings in the technical description, on the Enphase
System, and on the photovoltaic (PV) equipment.
NOTE: Using unapproved attachments or accessories may
result in damage or injury.
NOTE: When looping the Enphase Q Cable, do not form
loops smaller than 4.75 inches (12 cm) in diameter.
NOTE: Perform all electrical installations in accordance with
all applicable local electrical codes: the Canadian Electrical
Code, part 1; the National Electrical Code (NEC); ANSI
requirements; and NFPA 70.
NOTE: To ensure optimal reliability and to meet warranty re-
quirements, install the Enphase Field Wireable Connectors
according to the instructions in this guide.
NOTE: Protection against lightning and resulting voltage
surge must be in accordance with local standards.
NOTE: The connector is considered to be in compliance
with UL 6703 only when assembled in the manner specied
by these assembly instructions.
NOTE: Cable used with Enphase Field Wireable connectors
must meet the following requirements:
• Min/max outer insulation diameter (including the clear 2nd
insulator): 3.45mm / 3.65mm
• Number of conductor strands / size:19 strands of 0.47 mm
• Wire size: 12 AWG
Revision History
Rev 01 Initial release 02/21/2017.
Rev 02 Revised jacket strip length in step C - 04/10/2017.