Scenario 1: Simple 12 Module Scenario
Bill of Materials for Scenario 1: Simple 12 Module Scenario
QTY
Part Number
Description
12
IQ6PLUS-72-2-US
Enphase IQ 6+ Microinverter, compatible with 60- and 72-cell PV modules, 290VA
peak power, MC4 DC connectors, female AC connector
12 of 240
Q-12-10-240
Q Cable for 60/72 cell 1.0m portrait module pitch. Connector pitch is 1.3m. 240
Male connectors plus two bonus link connectors
0 of 10
Q-SEAL-10
Female sealing cap for unused Q Cable connectors. Pack of 10
1 of 10
Q-TERM-10
Q Terminator for Q Cable ends. Center feed requires two per branch. Pack of 10
21 of 100
Q-CLIP-100
Q Cable rail mount cable management clip. Pack of 100
1 of 10
Q-DISC-10
Disconnect tool for Q Cable connectors, MC and Amphenol DC connectors, and
AC module mount. Pack of 10
1
X-IQ-AM1-240-B M
Enphase IQ Combiner with IQ Envoy, 60A, single phase, revenue grade accuracy
(ANSI C12.20 +/- 0.5%) with calibrated solid-core CT