Installation Instructions

Ensemble Communications Inc.
3-10
Operators Guide to the Fiberless System
Ancillary Equipment
Note Although Ensemble recommends manufacturers, the Fiberless System
supports most standard-manufactured ancillary equipment.
Table 3-3: Ancillary Equipment Requirements
Equipment
Recommendation or
Requirement
Manufacturer and
Part Number
Required ODU cables Standard cable RG-6 Part No. Belden 9248
Plenum Cable RG-6
Not suitable for outside use
Part No. Belden 82248
Required ODU connectors TNC crimp connector for
Belden 9248 cable
Trompeter Electronics
Part No. UPL 240-020
TNC crimp connector for
Belden 82248 cable
Trompeter Electronics
Part No. 105-1457-10
Connector crimp tools TNC crimp tool Trompeter Electronics
Part No. CT4L
TNC crimp tool die Trompeter Electronics
Part No. CD3-3
8 point center pin tool Trompeter Electronics
Part No. 010-0055
Lightning suppressors Suppressor Kit Outdoor
Unit
PolyPhaser
Part No. 097-0619T-B.3
Suppressor Indoor Unit PolyPhaser
Part No. 097-0619T-B.4
Mounting Plate (12 indoor
units)
PolyPhaser
Part No. 100-0501S-A
Base station power
supply 48 VDC 50 Amps
(depending on
configuration)
Telephony-type modular
power systems
Power Conversion
Products Twin-pack Plus
series
CPE power 120 VAC Protection: small UPS
(Uninterruptible Power
System)
APC
Racks 19-inch or 23-inch. Any manufacturer
Base station routers DS-3 ATM interface and
fast Ethernet card
Cisco 7200 series
CPE routers v.35 interface Cisco 1601R
Dual 10BaseT ports Cisco 1605R
Tower mounts 2-4-inch pipe
Wall mount available
Microflect; Andrews, Tower
Structures