<timestamp> #000: Couldn’t open the file C:\SYSTEM\PLATFORM.NEI
The open operation failed, no further detail is available.
<timestamp> #0000: Error reading C:\SYSTEM\PLATFORM.NEI
The read operation failed, perform a software upgrade to reinstall the file.
<timestamp> #0000: Error reading platform type: there is no “plat name” field
There is no <platform name> value following the “=” character in the “current setting” string.
<timestamp> #0000: Error reading platform type: there was no “=” in the string
The “current setting” string has the format “<platform type>=<string>”. This error message
indicates that no = character exists in the string.
<timestamp> #0000: Error reading platform type: type value is too large
The <platform type> value in the “current setting” string is too large to represent an actual platform
type.
<timestamp> #0000: Error reading platform type: type was not converted to an int
The <platform type> value in the “current setting” string could not be converted to an actual
platform type.
1 port LAN Adapter, operating in remote mode only
This is an initialization message. It identifies the Ethernet adapter type (Ethernet-1), and operating
mode. Remote bridging is supported.
2 port LAN Adapter, operating in local and remote mode
This is an initialization message. It identifies the Ethernet adapter type (Ethernet-2), and operating
mode. Both local and remote bridging are supported.
aarp found duplicate AppleTalk address <AppleTalk Address> @ <MAC address>
The address resolution protocol found duplicate AppleTalk addresses for this AppleTalk network.
Check the configuration for the AppleTalk ports’ network range/number.
Abnormal response rcvd: <state msg reason cc state>
An unexpected message was received from a WAN interface card. The <parameters> included are
for problem reporting purposes only. If the system fails to operate normally, or the warning
continues to occur, contact your Distributor or Customer Support.
A call has exceeded the configured maximum duration
A call has been up longer than the amount of time configured. The next log message will inform
the user whether or not the call has been taken down.