- Cabletron Systems Remote Access Switch

USER’S GUIDE
714 CyberSWITCH
34 22 no circuit/channel available
Indicates that the connection could not be established because there
was no appropriate channel available to handle the call.
35 23 destination unattainable
37 25 degraded service
38 26 network (WAN) out of order
Indicates that the destination could not be reached because the
network was not functioning correctly and that the condition is
expected to last for a relatively long time. An immediate re-connect
attempt is likely to be unsuccessful.
39 27 transit delay range cannot be achieved
40 28 throughput range cannot be achieved
41 29 temporary failure
Indicates that an error has occurred because the network is not
functioning correctly, but that this problem is likely to be resolved
shortly.
42 2A switching equipment congestion (network congestion)
Indicates that the destination could not be reached because the
network switching equipment was temporarily overloaded.
43 2B access information discarded
Indicates that the network could not provide the requested access
information.
44 2C requested circuit/channel not available
Indicates that the remote equipment could not provide the requested
channel for an unspecified reason. This may, or may not, be a
temporary problem.
45 2D preempted
46 2E precedence call blocked
47 2F resource unavailable, unspecified
Indicates that the requested channel or service was unavailable for
an unspecified reason. This may, or may not, be a temporary
problem.
49 31 quality of service unavailable
Indicates that the requested quality of service (as defined by CCITT
recommendation X.213) could not be provided by the network. This
may be a subscription problem.
50 32 requested facility not subscribed
Indicates that the remote equipment supports the requested
supplementary service but that this is available only by subscription.
51 33 reverse charging not allowed
Dec Value Hex Value Q.931 Cause