Installation guide

Connecting the 5G102-06 to the Network
3-12 Installation
Figure 3-7 Connecting a Twisted Pair Segment to the 5G102-06
3. Verify that a link exists by checking that the port RX (Receive) LED is ON (flashing amber,
blinking green, or solid green). If the RX LED is OFF and the TX (Transmit) LED is not
blinking amber, perform the following steps until it is on:
a. Verify that the cabling being used is Category 5 UTP with an impedance between 85 and 111
ohms. If the port is to operate at 1000 Mbps, category 5 cabling must be used.
b. Verify that the device at the other end of the twisted pair segment is on and properly
connected to the segment.
c. Verify that the RJ45 connectors on the twisted pair segment have the proper pinouts
(Figure 3-8 and Figure 3-9) and check the cable for continuity. Typically, a crossover cable
is used between hub devices. A straight-through cable is used to connect between switches
or hub devices and an end user (computer).
d. If a link is not established, contact Enterasys Networks. Refer to “Getting Help” in About
This Guide for details.
4. Repeat all the steps above until all connections have been made.
35871_06
Gb ENET
5G102-06
RESET
COM
CPU
1
2
Receive LED
Transmit LED
RJ45
Connector