User manual
2.1.2.2 DHCP
If you want the device to obtain the IP address from the DHCP server, activate this
option. It is recommended to use this option only when the EMG Series device is
operating in client mode.
2.1.2.3 WEB Access
If you want the configuration of the device settings from the WEB interface, activate
this option.
2.1.2.4 WEB Port
You can configure the port which will be used for WEB access from here.
2.1.2.5 Log-in Time-out
When this set time passes after the WEB interface is closed without clicking on
“Exit” button on the interface page, the previous log-in information will be reset and
the user will be asked to enter the necessary information again.
2.1.2.6 Server IP
This option is only active when the EMG Series device is configured as client and
defines the server IP address to which the device will be connecting. If the device
fails to connect to the server, it will try to reconnect to the server in 1 minute
intervals. After the device connects to the server, it sends its MAC address to the
server to identify itself.
2.1.2.7 IP Address
It is for identifying the EMG Series device on the network. Each device on the LAN
must have a different IP address. If the device receives its address from DHCP
server, the IP address which is received from the DHCP server will be shown in this
area.
2.1.2.8 Subnet Mask
This number defines in which subnet the IP address is. If the device receives its
address from DHCP server, the IP address which is received from the DHCP server
will be shown in this area.
2.1.2.9 Default Gateway
This address enables the EMG Series device to access to WAN over a modem or a
router. If the device receives its address from DHCP server, the IP address which is
received from the DHCP server will be shown in this area.