Data Sheet
-
-
-
-
-
-
-
-
-
-
-
-
--
-
-
-
-
-
SPECIFICATIONS
MPR-24PM/MPR-24
ENCLOSURE
Dimensions
Protection Class
Display
MEASUREMENTS
Voltage
Measurement Range
Measurement Range with Transformer
Accuracy
Input Impedance
Burden (Input Load)
Current
Nominal Current
Minimum Current
Measurement Range
Measurement Range with Transformer
Burden
Overload Current
Short Time Overload (1s)
Power/Energy
Active Power
Reactive Power
Apparent Power
Power Factor
Active Energy
Reactive Energy
Total Harmonic Distortion (THD)
Separate Harmonics
Demand Period
Frequency
Sampling Period
SUPPLY
Operating Voltage
Operating Frequency
Power Consumption
DIGITAL INPUT / OUTPUT
Digital Input Pulse Width
Digital Input Operating Voltage
Switching Current
Digital Output Supply Voltage
Pulse Duration
Pulse Width
ANALOG OUTPUT
Current Output
Voltage Output
RELAY OUTPUT
Relay Output
TEMPERATURE INPUT
Sensor Input Type
Thermocouple Type
MEMORY
Internal Memory Size
COMMUNICATION
Communication Interface/Protocol
Transfer Speed
AMBIENT CONDITIONS
Operating Temperature
Storage Temperature
Overvoltage Category
Pollution Degree
Ambient Humidity
STANDARDS
Standards
CONNECTIONS
Mounting
Connection Terminals
Connection Types
DIN4 Rail Mounting
Terminals = IP20, Enclosure Protection Class = IP40
2,1 inch LCD screen
10-400 VAC (L-N) 10 - 690 VAC (L-L)
1-400.0kV Transformer Ratio: 1-5000
%0.5 ± 2 Digit
>1M Ω
<0,5 VA
In : 5A / 1A
5 mA
50 mA - 5,5 A Accuracy : %0.5 ± 1 Digit
50 mA -10000 A
<1 VA
1,2 In continuous
10xIn
0 - 1 GW Accuracy: %1 ± 1 Digit
0 - 1 GVAr Accuracy: %1 ± 1 Digit
0 - 1 GVA Accuracy: %1 ± 1 Digit
±1.00 Accuracy: ± 0,02
0 - 99 999 999 kWh or MWh Accuracy: %1 class 1
0 - 99 999 999 kVArh or MVArh Accuracy: %2 class 2
- 10 / +55 °C
- 20 / +70 °C
III
II
%95
EN 61557-12, EN 61326-1, EN 61000-6-2, EN 61000-6-3, EN 61000-6-4
EN 62053, EN 60068, EN 61010
Rail Mounting
Screw Terminal
3P4W, 3P3W, 3 Phase Aron, 3P4W Balanced, 3P3W Balanced
RS 485 / MODBUS RTU
2400-115200
1,2,5,10,15,20,30,60 min.
45-65 Hz
128
85 - 300 VAC/DC
50/60 Hz
<6 VA
PTC or Thermocouple type
B, C, K, R, S, T
20/500 ms
12...48 VAC/DC
Max 50mA
5-30 VDC (open collector)
100ms pulse period 80ms pulse width
20-500 ms (Adjustable)
0-20mA, 4-20mA, 4-24mA
0-5V, 0-10V, ±5V, ±10V
1 NO Contact, 250 VAC/5A 1 NO Contact, 250 VAC/5A
THD V%, THD I%
4MB
1-51 Voltage (V) and Current (I)
MPR-25S-22 MPR-26S-21 MPR-27S-23 MPR-28S-32 MPR-26S-21-PM
-
-
-
Compatible with
ENTES
current transformers.
Compatible
with ENTES
current
transformers.
ENTES Elektronik Cihazlar İmalat ve Ticaret A.Ş.
HEADQUARTERS
Address: Dudullu OSB; 1. Cadde; No: 23 34776 Ümraniye - İSTANBUL / TÜRKİYE Tel: +90 216 313 01 10 Fax: +90 216 314 16 15 Sales Fax: +90 216 365 71 71
E-mail: impex@entes.com.tr Web: www.entes.com.tr E-bulletin membership: ebulten@entes.com.tr Coordinates: 40,995852 N, 29,178398 E
INTERNATIONAL BRANCH OFFICES
İSTANBUL : impex@entes.com.tr Tel: +90 216 313 01 10 Fax: +90 216 314 16 15
NETHERLANDS : info@entes.eu Tel: +31 412 - 644319
GREECE : infohellas@entes.eu Tel: +30 2310 706999 +30 2310 707296