0 IP1725EN - 2015-05-14 All the rights concerning this material are the exclusive property of Entrematic Group AB. Although the contents of this publication have been drawn up with the greatest care, Entrematic Group AB cannot be held responsible in any way for any damage caused by mistakes or omissions in this publication. We reserve the right to make changes without prior notice. Copying, scanning and changing in any way are expressly forbidden unless authorised in writing by Entrematic Group AB.
Index Subject Page 1. General safety precautions 22 2. Declaration of incorporation of partly completed machinery 24 2.1 Machinery Directive 24 3. Technical specifications 25 3.1 Operating instructions 4. 25 Standard installation 26 4.1 Dimensions 27 Installation 28 5. 5.1 Preliminary checks 28 5.2 Geared motor installation 28 6. Electrical connections 30 7.
1. General safety precautions This installation manual is intended for qualified personnel only. Installation, electrical connections and adjustments must be performed by qualified personnel, in accordance with Good Working Methods and in compliance with the current regulations. Read the instructions carefully before installing the product. Bad installation could be dangerous. The packaging materials (plastic, polystyrene, etc.
IP1725EN - 2015-05-14 General safety precautions for the user These precautions are an integral and essential part of the product and must be supplied to the user. Read them carefully since they contain important information on safe installation, use and maintenance. These instructions must be kept and forwarded to all possible future users of the system. This product must only be used for the specific purpose for which it was designed. Any other use is to be considered improper and therefore dangerous.
2. Declaration of incorporation of partly completed machinery (Directive 2006/42/EC, Annex II-B) The manufacturer Entrematic Group AB, with headquarters in Lodjursgatan 10, SE-261 44 Landskrona, Sweden, declares that the automation for swing gates type Ditec ARC: - is designed to be installed on a manual gate to form a machine pursuant to Directive 2006/42/ EC.
3.
4.
4.1 Dimensions 130 147 364 8 360 30 9 150 150 30 100 Ø9 54 Ø9 45 30 65 30 65 45 370 10 Ø9 10 60 60 IP1725EN - 2015-05-14 200 Ref.
5. Installation Unless otherwise specified, all measurements are expressed in millimetres (mm). 5.1 Preliminary checks Check that the structure is sufficiently rugged and that the hinge pivots are properly lubricated. Provide an opening and closing stop. 5.2 Gearmotor installation - Disassemble the reduction gear from the fastening plate [9].
- Attach articulated arms, as shown in figure. Attention: bring the leaf to the stop line, align the arms by means of holes [A] - The articulations on the arms should be lubricated and the screws tightened in such a way as not to block arm movement. 40 A - Drill the cover Ø14 near release shaft [B] (there are two drilling templates [C] inside the cover). - Insert the rubber plug and attach the cover to the geared motor.
6. Electrical connections Before connecting the power supply, make sure the plate data correspond to that of the mains power supply. An omnipolar disconnection switch with minimum contact gaps of 3 mm must be included in the mains supply. Check that upstream of the electrical installation there is an adequate residual current circuit breaker and a suitable overcurrent cutout.
Operating instructions IP1725EN - 2015-05-14 DETACH AND DELIVER TO THE CUSTOMER General safety precautions for the user These precautions are an integral and essential part of the product and must be supplied to the user. Read them carefully since they contain important information on safe installation, use and maintenance. These instructions must be kept and forwarded to all possible future users of the system. This product must only be used for the specific purpose for which it was designed.
IP1725EN - 2015-05-14 DETACH AND DELIVER TO THE CUSTOMER must not be carried out by children unless they are supervised. To ensure that the system works efficiently and correctly, the manufacturer’s indications must be complied with and only qualified personnel must perform routine maintenance on the motorised door or gate. In particular, regular checks are recommended in order to verify that the safety devices are operating correctly.
Manual release instructions 1 2 IP1725EN - 2015-05-14 DETACH AND DELIVER TO THE CUSTOMER In case of faulty operation or power failure, remove the plug and insert the release key supplied in the special hole on the cover. Turn clockwise to release the right leaf; counterclockwise to release the left leaf. Manually slide the gate open. At end of operations, lock the geared motor again. WARNING: the door wing block and release operations must be performed with the motor idle.
IP1725EN - 2015-05-14 Entrematic Group AB Lodjursgatan 10 SE-261 44, Landskrona Sweden www.ditecentrematic.