Installation Instructions

24
IP1812EN - 2015-05-22
3. Technical data
CUBIC6 CUBI6H CUBIC6HV
Power supply 230 V~ 50 �z 24 V 24 V
Absorption 1,5 A 12 A 12 A
Couple 340 Nm 340 Nm 220 Nm
Capacitor 10 µF - -
Opening time 18 s/90° 12÷25 s/90° 6÷13 s/90°
Max opening 110°-180° (see page 26) 110°-180° (see page 26) 110°-180° (see page 26)
Service class 3 - FREQUENT 4 - INTENSIVE 4 - INTENSIVE
Intermittence
S2 = 15 min
S3 = 25%
S2 = 30 min
S3 = 50%
S2 = 30 min
S3 = 50%
Temperature
min -20° C max +55° C
min -35° C max +55° C
(with NIO enabled)
min -20° C max +55° C
min -35° C max +55° C
(with NIO enabled)
min -20° C max +55° C
min -35° C max +55° C
with NIO enabled
Degree of
protection
IP67 IP67 IP67
Control panel E2 - LOGICM VIVA� VIVA�
Applications
m = leaf width
kg = leaf weight
600 kg
700 kg
800 kg
500 kg
400 kg
300 kg
200 kg
100 kg
m1234 5
600 kg
500 kg
400 kg
300 kg
200 kg
100 kg
m1234 5
3.1 Operating instructions
Service class: 3 (minimum 30 cycles a day for 10 years or 60 cycles a day for 5 years).
Use: FREQUENT (For vehicle or pedestrian accesses to town houses or small condominiums with
frequent use).
Service class: 4 (minimum 100 cycles a day for 10 years or 200 cycles a day for 5 years)
Use: INTENSIVE (For vehicle or pedestrian accesses to large condominiums, industrial or
commercial complexes and parking lots with very frequent use).
- Performance characteristics are to be understood as referring to the recommended weight
(approx. 2/3 of maximum permissible weight). When used with the maximum permissible
weight a reduction in the above mentioned performance can be expected.
- Service class, running times, and the number of consecutive cycles are to be taken as merely
indicative �aving been statistically determined under average operating conditions, and are
therefore not necessarily applicable to specifi c conditions of use.
- Each automatic entrance has variable elements such as: friction, balancing and environmental
factors, all of which may substantially alter the performance characteristics of the automatic
entrance or curtail its working life or parts thereof (including the automatic devices themsel-
ves). The installer should adopt suitable safety conditions for each particular installation.
CUBIC6L