User's Manual

EZBee series Manual / Ver. 1.0
45
7.10.3
7.10.37.10.3
7.10.3 ADC
ADC ADC
ADC reading
readingreading
reading
The status value of a local or remote modem can be checked by
following AT commands.
Command Parameter Result Description
AT+ADC?
None < CH1>,<CH2>
Read the ADC status value of a
local modem
AT+ADC@
<DstID>?
OK
Read the ADC status value of a
remote modem
The ADCs in EZBee modem are 2 channels having 10 bit resolution,
and operated based on 3.3V reference voltage.
The status value of the ADC is expressed as ASCII HEX format. For
example, if 1.25V and 2.5V are inputted onto channel 1 and channel 2,
respectively, the ADC status values are expressed as 060F and 0C1E.
When the command for a remote modem is accomplished successfully,
a following event message is returned.
.
Message Parameter
Description
$ADC@
<DstID>=<CH1>,<CH2>
Return ADC status value of a remote modem
<DstID>
7.11
7.117.11
7.11 Remote control
Remote controlRemote control
Remote control
allowance setting
allowance settingallowance setting
allowance setting
In the EZBee formats, the allowance is selectable whether it make a
remote modem control the GPIO or change parameters of a local modem
in the PAN.