Operating instructions
OUTSIDE AIR: 
Pedestal 
rear
A 4” (10.16 cm) fresh air adapter kit is available. This adapter can be installed either 
on the back pedestal or through the floor under the pedestal. 
Place the ¼” mesh screen between the fresh air adapter and the body of the 
pedestal. (AS SHOWN) 
NOTE: Fresh air connection to the unit must be a non combustible pipe. 
(Example: 4” (10.16 cm) single wall aluminum flex pipe) 
NOTE: REMOVE THE 4” KNOCK OUT ON THE REAR OF THE 
PEDESTAL IF ROOM AIR IS TO BE USED FOR 
COMBUSTION AIR 
ALCOVE INSTALLATION;
Model 1000 May be installed with double wall pipe in an alcove up to 4 
ft. (1.2 m) deep and at least 7 ft. (2.13 m) high: sides 14” and rear 6”. 
Model 1600 May be installed with double wall pipe in an alcove up to 30” (76 cm) deep and at least 70” (178 cm) 
high and a minimum width of 48” (122 cm) 
FLOOR PROTECTION: 
If a stove is installed on a combustible floor, it must have a pedestal attached and be on a NON COMBUSTIBLE 
hearth pad extending at least 8” (200 mm) to each side, and 18” (455 mm) to the front as indicated below. 
TO INSTALL A LISTED, FACTORY BUILT CHIMNEY. 
1. Set floor protector and stove in location in accordance with the clearances required 
above (see previous page). 
2. Mark the position for the ceiling hole by using a plumb bob. 
3. Move this location, if necessary, to avoid floor joists, ceiling rafters while still maintaining 
required clearances (see manufacturer’s label on page 15 or the clearances to 
combustibles on page 8). 
4. Mark the hole for the outside air kit. 
5. Move the stove out of the way. 
6. Cut a pilot hole in the ceiling. 
7. Cut a hole for the ceiling penetration components and frame in the sides of the hole in 
both the ceiling and roof. Check, and follow chimney manufacturer’s instructions for all 
of these steps. 
8. Install the support box and chimney through the roof. Install the slip section for the 
chimney connector. 
9. Slip the roof flashing over the chimney and secure to the roof, being careful to keep the 
pipe centered in the opening. To meet the code, the chimney must extend above the 
roof at least 3 FT. (91.44 cm), and 2 FT. (60.9 cm) above any area of the roof, within 10 
FT. (304.8 cm) of the end of the chimney. 
10. Be sure all pieces including outside rain cap, flange, collar and pipe are installed and then place the stove 
back into position. 
11. Install the smoke pipe with the lower (crimped) edge of the pipe inside the smoke collar. Any creosote formed 
will then run back down into the stove. All connections must be tight and secured with three sheet metal 
screws equally spaced. 
12. Also install an outside air flex pipe to the stove. 
12