Owner`s manual

Maintenance And Service
QUALIFIED INSTALLERS ONLY
gLass DooR RemoVaL:
Blower / Fan
Gas & Electrical
Tray Complete
Burner Top with
Grate Attached
Log Support
Tray
Figure 10: Removing burner and gas tray.
1. Turntheunitoffandallowtheunittocool
completely.
2.Removethefasciaorlouvers,openthedoor
(seemaIntenance anD serVIce - glass Door
remoVal),andremovethelogset.
3.Remove the log support tray by lifting the
backofthetrayupandpullitoutfromunder
thelip.Takecaretonotknockthepilotand
thesidebrickpanels.
4.Removethecentreandtopbrickpanels(see
seconDary InstalatIon - remoVIng the brIck
panel).
5.Turn gas supply off and remove gas
connection.Disconnectthewiringfromthe
sideoftheappliance.
6.Remove the three (3) T-20 screws just
above the burner top on the back rewall
(seeFigure10)andthetwo(2)screwson
each side below the burner top. Carefully
Figure 8: Top bolts for glass door.
Figure 9: Bottom hooks for
glass door.
10
Openthedoorbyremovingthetwo(2)
5
/16’’ bolts located at the top outside
cornersoftheglassframe(seeFigure
8).Liftthebottomofthedoorupand
removefromunit(seeFigure9).
CAUTIONGLASSMAY
SEPARATEFROMDOOR.
removethecompletegasandelectricaltrayassemblyfromtherebox,ensuringthatnowiresorgas
linesaredamaged.
7.Removetheblowerandhousingfromthegastrayassemblybyremovingthethree(3)fasteningscrews
locatedonthebackofthegastrayassembly.Pullthefanoutfromunderthegastray.Disconnectthe
wiringfromthefantemperaturesensorandremovefan.
8.Hookupwiresfromthenewblowertomainwiringharnessandfantemperaturesensor.Installthe
blowerinthereverseorderasdescribedinStep7.
6.Reinstallthecompletedgastrayintotherebox,beingcarefulnottodamageanywiresorgaslines.
Properlysecurethegastrayassemblyintherebox.Hookupgaslinesandwiringharness.Performa
gasleakcheckonallgaslinewithasoapandwatersolutionoranapprovedmethod.
7.Returnunittooriginallocationifmoved.Re-installthelogsupporttray,thebrickpanels,thelogset
(seeseconDary InstalatIon - log set anD ember InstallatIon),thedoorandthefasciaorlouvers.
8.Checkburnerandblowerassemblyforproperoperation.
Caution: Bleed lines before lighting and light pilot with door open.
buRneR & bLoweR RemoVaL: