Owner`s manual

12
Maintenance And Service
b) Insert a
5
/32” or 4 mm Allen wrench into the
hexagonalkey-wayofthescrew(seeFigure12),
rotate it counter-clockwise until it is free and
extractit.
c) Check that the screw is clean and if necessary
removedirt.
d) Flipthescrew(refertoFigure13).
e) Using the Allen wrench as shown in Figure 12,
rotatethescrewclockwiseuntilatorqueof9inch
lbs.WARNING!Donotovertightenthescrew.
Itisrecommendedthatyougripthewrenchby
theshortside.
f) VerifythatiftheconversionisfromNGtoLPG,
thescrewmustbere-assembledwiththeredo-
ringvisible(refertoFigure14).Iftheconversion
isfromLPG to NG,thered o-ring ofthescrew
mustbenotvisible.
Figure 13: Flip valve
screw.
Red o-ring
is not visible
Red o-ring
is visible
LPG Configuration
g) Re-attach the black protection
cap that was removed in step a
(Figure11).
8. Reinstall the burner, brick panels,
logset,embers,andglassdoor.Also
refer to seconDary InstallatIon -
InstallIng log set anD embers. When
re-installingtheburner,ensurethat
theburnertopilothoodrelationship
Figure 14: O-ring on valve screw.
issimilartowhatisshowninFigure15.Onsomeunitsyouwillneed
to payspecialattentionwheninstallingtheburnerthattheventuri
adjustmentrodisproperlyinstalledintotheventuriadjustmentpiece
weldedtotheburnerventuritube
9. Reconnect the main gas line if it was disconnected and open the
shut-offvalveatthegaslinetotheunit.
10.Useasmallbrushtoapplyawarmsoapywatersolutiontoallgas
connections(usehalfdishsoapandhalfwarmwater).Ifagasleak
ispresent,bubbling will occur. Gas leakscanbe repaired by using
an approved pipe thread sealant or approved Teon tape. NEVER
USE AN OPEN FLAMEWHEN TESTING FOR LEAKS. Check the gas
Loosen
Tighten
Figure 12: Removing valve
screw.
pressureoftheappliance,refertoInItIal InstallatIon - gas lIne connectIon andTable5.
11. Reconnect the electrical power to the unit.
12. Lightthepilotandcheckforproperames(seeFigure4).Lighttheburnerinbothhighandlow
settingstoverifyproperburnerignitionandoperationandproperameappearance.Theamount
ofairtotheventurimayneedtobeadjustedusingtherodundertherebox(refertooperatIng
InstructIons - aDjustIng VenturI aIr settIngs). Also refer to Figure 37 for a ame appearance
picture.
13. MAKESUREthattheconversionlabelisinstalledonorclosetotheratinglabeltosignifythatthe
unithasbeenconvertedtoadifferentfueltype.
Figure 15: Burner to pilot hood
relationship.