Owner`s manual

Initial Installation
WARNING: Operationofthisheaterwhennotconnectedtoaproperlyinstalledand maintained
ventingsystemcanresultincarbonmonoxide(CO)poisoningandpossibledeath.
cLeaRances to combustibLes:
Maintainsufcientclearancesforoperation,serviceandmaintenance.
• Aclearanceof25½”(648mm)minimumisrequiredfromthecenteroftheunittothesidewalls.
10" (254mm) Mantle
2" (51mm)
Mantle
39" (991 mm)
minimum to
bottom of unit
43" (1092 mm)
minimum to
bottom of unit
Figure 16: Mantle width and height.
• A 2” (51 mm) wide mantel can be mounted at a
minimumheightof39”(991mm)fromthebottom
of unit.
• A10”(254mm)widemantelcanbemountedata
minimumheightof43”(1092mm)fromthebottom
of unit.
• Ifinstalledatoorlevel,aminimum16”(406mm)
non-combustiblematerialmustbeinstalledinfront
of the unit.
• Ifinstalledona12”(305mm)widehearthraiseda
minimumheightof6”(152mm),nooorprotection
isrequired.
• Refer to Figure 17 for additional required oor
protectiondimensionswithdifferentwidthhearths.
Sienna
0" (0mm)
5" (127mm)
6" (152mm)
7" (178mm)
8" (203mm)
9" (229mm)
10" (254mm)
11" (279mm)
12" (305mm)
13" (330mm)
14" (356mm)
15" (381mm)
16" (406mm)
Hearth Height
of 6" (152mm)
Non-combustible
floor protection required
in front of corresponding
hearth width
6" (152mm)
11" (279mm)
12" (305mm)
EXAMPLE: If the Sienna is raised
6" (152mm) and has 4" (102mm)
wide hearth in front of it then 12"
(305mm) of non-combustible
floor protection is require to
be installed in front of the
hearth.
Figure 17: Floor protection distance required.
13