Owner`s manual

14
Initial Installation
Check draft with a match
or smoke in a ¼" (6 mm)
tube located here.
minimum fiRePLace size:
DescriptionofFireplaceDimension DirectVent B-Vent
Width
AtBack 23¼”(591mm) 23¼”(591mm)
AtFront 35”(889mm) 35”(889mm)
Height
WithSurroundOnly 23¾”(603mm) 23¾”(603mm)
WithSurroundwithTrim 23”(584mm) 23”(584mm)
Depth
WithSurroundOnly 18”(457mm) 19”(483mm)
WithSurroundwithTrim 16½”(419mm) 17½”(445mm)
ChimneyFlueSize 7”(178mm)x7”(178mm) 5”(127mm)x5”(127mm)
b-Vent moDeL:
WARNING: Thisappliancehasbeendesignedtooperatebydrawingcombustionairanddilutionair
fromtheroom.Itisalsodesignedtodrawroomairforproperheatcirculationfromthesidesofthe
unit.Blockingormodifyingthelouversinanywaycancreatehazardoussituations,eitherthroughpoor
ventingorbyoverheating.Itisimportantthatthisunithassufcientaircirculationforproperventing
andcombustion.Provisionsmustbemadeforthesupplyofadequatecombustionandventilationair.
Theseopeningsmustnotbeblocked.Theappliancemustnotbeconnectedtoachimneyueservicing
aseparatesolidfuel-burningappliance.
automatic fLue gas sPiLL switch - b-Vent moDeL onLy:
NOTE: This heater must be properly connected to a venting system. This heater is equipped
with a vent safety shutoff system designed to protect against improper venting of combustion
products. This safety switch is located on the rear of the appliance. If the switch trips more
than once, the venting should be inspected by a qualied service technician for possible
blockage or severe down draft conditions.
WARNING:
Operationof thisheaterwhennotconnectedtoaproperlyinstalledandmaintained
ventingsystemcanresultincarbonmonoxide(CO)poisoningandpossibledeath.
The draft hood must be in the same pressure zone as
theairinlet.Inspectfordraftfromthefrontoftheunit
at the ¼” tube shown in Figure 18. Check for a draft
using smoke; a vacuum or suction into the tube will
indicateproperdrafting.Ifairisblowingoutofthetube
the problem must be corrected before the unit can be
started.
Thismodelcanbeventedwith4”aluminumorstainless
steel ex vent and/or certied Type B Gas Vent. The
ue collar of the appliance will t inside of a standard
4”ventandmaybefasteneddirectlytothevent.Check
periodicallythattheventisunrestrictedandanadequate
draftispresentwhentheunitisinoperation.
Figure 18: Draft check.
Table 2: Minimum dimensions of replace for Sienna to be installed into.