Initial Installation
QUALIFIED INSTALLERS ONLY
conVeRting a DiRect Vent fiRePLace to a b-Vent fiRePLace:
Direct Vent
Connector Assembly
Fresh Air
Inlet Covers
1. Remove the Direct Vent
chimney connector assembly
bytakingoutthetwo(2)T-20
screws at the front of the unit.
Push the assembly out from
underthebracketsattheback
andremove(seeFigure24).
2.Remove the two (2) fresh air
inlet covers from each side.
Cover locations shown in
Figure25.
3.Slide the B-Vent chimney
connector assembly into the
same position the Direct Vent
chimney connector assembly
was in. Ensure the tabs are
underthebracketsattheback
andtheholesatthefrontline
up.Secureintoplacewiththe
two (2) T-20 screws at the
front of the unit.
4.Disconnect the two (2) blue
wires at the opening to the
right of the unit and connect
them to the 300°F (149°C)
manual reset spill switch at
the rear of the B-Ventchimney
connector with the wires
supplied.RefertoFigure26.
5.Test re the appliance and
ensure proper operation. A
venturi adjustment could be
requiredtoachieveanefcient
ame. Improper operation
or adjustment could result in
Carbon Monoxide production
causing personal injury or
propertydamage.
Figure 25: Converting to a BV replace.
B-Vent
Connector Assembly
300°F (149°C)
manual reset
spill switch
Figure 26: Converting to a BV replace.
20