Initial Installation
QUALIFIED INSTALLERS ONLY
ELECTRICAL SYSTEM:
The replace must be electrically connected and grounded in accordance with local codes or, in the absence of local
codes, with the current CSA C22.1 CANADIAN ELECTRICAL CODE Part 1, SAFETY STANDARDS FOR ELECTRICAL
INSTALLATIONS, OR THE NATIONAL ELECTRICAL CODE ANSI / NFPA 70 in the US.
Figure 25. Wiring Diagram For Fan Control.
WARNING: The electrical grounding instructions
must be followed. This appliance is
equipped with a three-prong (grounding)
plug for your protection against shock
hazard, and should be plugged directly
into a properly grounded three-prong
outlet. DO NOT cut or remove the
grounding prong from this plug.
CAUTION: When servicing controls, label all
wires prior to disconnection. Wiring
errors can cause improper and dangerous
operation. Verify proper operation after
servicing.
Figure 26. Wiring Diagram For Gas Valve.
Recommended Thermostat Wire Size:
Wire Size Max. Length
14 ga. 100 ft (30.48m)
16 ga. 60 ft (18.29m)
18 ga. 40 ft (12.00m)
20 ga. 25 ft (7.62m)
22 ga. 18 ft (5.49m)