Owner`s manual

Codes And Approvals
DIRECT VENT: This type is identied by the prex DV. This appliance draws all of its air for
combustion from outside the dwelling, through a specially designed vent pipe system.
** TOP VENT DV ONLY** Certied for installation from 0-4500 FT (1372 M)
This appliance has been tested and approved for installations from 0 ft. to 4500 ft. above sea level.
In the USA:
The appliance may be installed at higher altitudes. Please refer to your American Gas Association guidelines which
state: the sea level rated input of Gas Designed Appliances installed at elevations above 2000 ft. is to be reduced
4% for each 1000 ft. above sea level. Refer also to local authorities or codes which have jurisdiction in your area
regarding the de-rate guidelines.
In Canada:
When the appliance is installed at elevations above 4500 ft. (1350 m), the certied high altitude rating shall be
reduced at the rate of 4% for each additional 1000 ft. (300 m).
These appliances have been tested by INTERTEK (Warnock Hersey) and found to
comply with the established VENTED GAS FIREPLACE HEATER standards in CANADA and the
USA as follows:
VENTED GAS FIREPLACE HEATER (DV42DX) (NG/LPG)
TESTED TO: ANSI Z21.88a.2002 CSA 2.33a.2002 VENTED GAS FIREPLACE HEATER
CAN/CGA 2.17-M91 GAS FIRED APPLIANCES FOR HIGH ALTITUDES
ENVIROGAS DV42DX Fireplace
Has been certied for use with either natural or propane gases. (See rating label.)
Is not for use with solid fuels.
Is approved for bedroom or bed sitting room. (Canada must install an approved wall
thermostat)
Must be installed in accordance with local codes. If none exist, use current installation code
CAN/CGA B149 in Canada or ANSI Z223.1/NFPA 54 in the USA.
Must be properly connected to a venting system and not connected to a chimney ue
serving a separate solid-fuel burning appliance.
4