Owner`s manual

Operating Instructions
For Your Safety, Read Safety Precautions And
Lighting Instructions Before Operating
WARNING: IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY A FIRE OR EXPLOSION MAY
RESULT, CAUSING PROPERTY DAMAGE, PERSONAL INJURY OF LOSS OF LIFE.
A) Make sure the pilot is lit.
B) Turn gas control knob COUNTER CLOCKWISE to ON.
C) Flip the burner switch to ON.
D) Turn HI/LO knob to the desired ame height.
E) Turn on all electrical power to the unit.
NOTE: Check that all burner holes are lit.
TO TURN GAS FIREPLACE OFF
Flip switch to OFF to turn off burners only.
If the replace is to be turned off for the season, or for
servicing, turn the gas shut off valve to OFF. DO NOT
FORCE IT. If the unit is going to be serviced, turn off the electrical power to the unit as well.
NOTE: When the unit is turned on for the rst time, it should be turned onto high, with the fan OFF, for the rst
four hours. This will cure the paint, logs, gasket material, and other products used in the manufacturing process.
It is advised that a door or window be opened as the unit will start to smoke, which can irritate some people. After
the unit has gone through the rst burn, turn the unit OFF, including the pilot, and let the unit get completely cold.
Then remove the glass and clean it with a good gas replace glass cleaner, available at your local Envirogas dealer.
See page 23 for glass removal and page 8 for glass cleaning information.
REMOTE CONTROLS:
This replace can use an optional remote control or an optional cordless wall thermostat. If either of these are
to be used to control the replace for the majority of the time, leave the ON/OFF switch (on the control panel) in
the remote/thermostat position. Consult the instructions included with the remote/wall thermostat for operation
guidelines.
When the blower is on, the amount of air ow into the room can be ajusted
with the air diverter. when the lever is to the far left the room receives the
air, when the lever is to the far right the air goes out the duct and when the
lever in the middle the air goes to both the duct and the room. Lever is found
above the right end of the control panel, see gure 4.
BLOWER SPEED:
The blower will come on only when the replace is up to temperature (approx 20 minutes).
The speed of the fan can be changed by turning the fan control knob. To turn the blower
off, turn the knob COUNTER CLOCKWISE until it “clicks” off (Figure 5).
It is advisable not to operate the blower below 1/3 speed as it puts a strain on the windings
of the blower and running the blower at lower speeds could also cause premature fan
failure.
Figure 3. Control Panel
Figure 5. Fan Control
7
BURNER LIGHTING:
R
o
o
m
D
u
c
t
A
i
r
D
i
v
e
r
t
e
r
Figure 4. Air Diverter
AIR DIVERTER CONTROL: