Owner`s manual
Maintenance And Service
FUEL CONVERSION:
Warning: A qualied service technician, in accordance with the manufacturer’s instructions
as well as all applicable authority having jurisdiction, shall install this conversion kit.
If the information in these instructions is not followed exactly, a re, explosion or
CO poisoning, may result. The qualied service agency is responsible for the proper
installation of this kit. The installation is not proper or complete until the operation of
the converted appliance is checked as specied in the owner’s conversion kit.
Please read and follow these instructions. Also, please read the instruction guidelines provided by S.I.T. on how to
remove and install the HI/LO regulator.
Step 1. Carefully inspect all parts supplied with this conversion kit.
Step 2. Shut the gas off at the shut off valve.
Step 3. Remove the glass as shown in the Secondary Installation section.
Step 4. Change the regulator on the front of the gas valve (Follow the instructions provided by S.I.T.)
Step 5. To change the pilot, simply pull the pilot hood straight up to access the pilot injector. Using a
5
/32in Allen
key, remove the pilot injector.
Step 6. Install the new pilot injector supplied with this conversion kit. Simply screw the new injector inside the pilot
hood and reinstall the hood by placing the hood on the assembly, lining up the key way, and snap into place.
Step 7. Remove the main burner orice with a in deep socket.
Step 8. Install the new orice supplied. Be sure to put a bead of pipe thread sealant or approved Teon tape on
the orice before installing into the burner assembly.
Step 9. Reinstall the burner tray, log set, embers, and glass.
Step 10. Open shut off valve at the gas line to the unit.
Step 11. Re-light the replace to ensure proper operation and proper ame appearance.
Step 12. MAKE SURE that the sticker provided by S.I.T. is installed, to signify that the valve has been converted
to a different fuel type. Also, make sure that the rating plate has a conversion label to show this unit has been
converted to a different fuel type.
A VISUAL CHECK OF THE REGULATOR KNOB IS NECESSARY TO DETERMINE WHETHER OR NOT THE REGULATOR
IS THE CORRECT PART. A 50% TURN DOWN REGULATOR WILL HAVE ONLY ONE CORNER ON THE KNOB
Conversion Kits should contain the following:
1 50% turn down HI/LO regulator NATURAL GAS PROPANE GAS
with 3 T-20 Torx screws Pilot Orice: 2.82mm 1.70mm
1 Pilot injector Burner Orice: #34 DMS #51 DMS
1 Main orice
Conversion instructions
Labels to show conversion
9