Specifications

14
INSTALLING YOUR ROOM HEATER
Your first step is to decide where to install your pellet stove. In order to get the best use
of circulated heat we recommend too install it in a large open room centrally located in
the house.
Next it is very important to check that clearances to combustibles are maintained, these
can be found on page 14 of this manual and on the rating label of the pellet stove.
The pellet stove can be vented through an exterior wall or into an existing masonry or
metal chimney. The chimney must be lined if over 6” (150 mm) in diameter or if it has a
cross sectional area of over 28 square inches. Venting can pass through the ceiling and
roof if listed pipe is used.
Do not obtain combustion air from the attic, garage or any other unventilated area. You
may obtain combustion air from a ventilated crawlspace.
DO NOT INSTALL A FLUE DAMPER IN THE EXHAUST VENTING SYSTEM OF
THIS UNIT.
DO NOT CONNECT THIS UNIT TO A CHIMNEY FLUE SERVING ANOTHER
APPLIANCE.
INSTALL VENT AT CLEARANCES SPECIFIED BY THE VENT
MANUFACTURER.
This appliance is certified for use with listed “PL” or “L” pellet venting products as well
as Selkirk’s Direct-Temp Vent system for pellet burning appliances..