Owner`s manual
Operating Instructions
FOR YOUR SAFETY READ COMPLETELY BEFORE OPERATING.
LIGHTING INSTRUCTIONS:
6
CAUTION:
Hot while operating. Do not touch. Keep children, clothing,
furnit ure, gasoline or other flammable vapors away.
FOR YOUR SAFETY: Do not operate this fireplace with the glass removed, cracked or broken.
Replacement of this glass should be done by a licensed or qualified person! This appliance needs fresh
air for safe operation and must be installed with provisio ns for combustion and ventilation air.
See installation and operating instructions manual. Keep burner and control compartment clean .
Improper installation, adjustment, alteration, service or maintenance can cause property
damage, personal injury, or loss of life. Refer to owners manual. Installation and service must be
performed by qualified installer, service agency or the g as supplier.
WARNING:
TO TURN OFF GAS TO APPLIANCE
1.
2.
Fli p burn er switch to “OFF”
Turn the gas co ntrol k nob clockwise to th e “OF F”
po sition
3 . Turn off all electrical po wer to the ap pliance if service i sto
be performe d.
ACLIE -1
FOR YOUR SAFETY READ BEFORE OPERATING
WARNING: IF YOU DO NOT FOLLOW THESE INSTRUCTIO NS EXACTLY, A FIRE O R EXPLOSION MAY RESULT CAUSING
PROP ERTY DAMAGE, PERSONAL INJURY OR LOSS OF LIFE.
A)
B) BEFORE LIGHTING
WHAT TO DO IF YOU SMEL L GAS:
This appliance is e quippe d with a pilot, which must be lit by
hand
smell all around the appliance area
f or gas
Do not try t o light any a pplian ce. Do not touch a ny electrical
switc h:
Immediately call your gas sup plier f rom a neighbors phone.
Follo w
b y following these instructions e xactly.
and n ext to the floor because some gas is heavi er
t han air and will se ttle on the floor.
do not use any phone in your building.
the gas suppliers instr uctions.
If you cannot re ach y our gas supp lier, call the fire departm ent.
Use only your ha nd to p ush in or tu rn the gas co ntrol knob,
Call a qual ified s ervice technician. Force or
Do n ot use thisa pplian ce if any part has b een u nder water.
C)
D)
Neve r use tools. If the k nob will not push in or turn by
hand , do n ot try to rep air it.
attempte d
repair may result in a fire or explosion.
Immediately call a qualified service technician to inspe ct
the a ppliance an d to replace any part of t he con trol system
and any ga s con trol which has been unde r water.
LIGHTING INSTRUCTIONS
1.
2.
3.
4.
5.
ST OP! Read th e safe ty information above on th is labe l.
Turn off all electrical power to this applian ce.
Turn off t he gas contr ol knob clock wise to the off
position.
Open door. Wa it five (5) minutes to clear outany gas.
Cl ose do or.
If you do not smell gas go to the ne xt ste p
Find pilo t-locate d to th e righ t behin d the side log. Turn
the gas c ontrol
If you smell gas, includ ing ne ar the floor ,
ST OP! Follow “ B” in the above safety inf ormation.
kn ob cou nter-clockwise to “PILOT”.
Push the gas co ntrol in
ful ly and hold, Keep knob
depressed for a bout 30 seco nds after
pilot is lit. Release kno b. If p ilot goes out ,
rep eat st eps 4 t hrough 5.
: this gas valve ha s a loc kout device, whichwill
n ot allow
stop and imme diately
I f the pilot does not stay lit after several tries, turn the gas
control
Turn the gas control knob counter clockwise t o the
“ON”
Turn on the ele ctrical power to the unit.
WARNING
6.
7.
the pilot burner to be relit until the ther mocouple
h as cooled. If the knob does not po p up when released,
call yo ur service tec hnician or gas
supplier.
knob to “OFF” and call your service technician or
g as supplier.
position. Flip the burner switch to
“ON” THEN TURN THE “HI/LOW” knob to the desired setting.
Figure 3. Lighting instruction label.
PILOT LIGHT:
1. Turn off the gas to the replace. If not recently done, remove the glass and let the unit air out
for at least ve (5) minutes to clear out any gas. Turn on gas to the heater. Leak test all joints
with soapy water. NEVER USE AN OPEN FLAME FOR
LEAK TESTING.
Figure 4. Pilot ame.
2. Start the pilot by pressing the gas control knob and turning it to PILOT. While
holding the gas control knob in, press the piezo ignitor several times until the
pilot light starts. Hold the gas control knob in for thirty (30) seconds. Check
that the pilot has fully engulfed the thermocouple assembly (see Figure 4).
3. Start the main burner by turning the gas control knob to ON and then turn
the rocker switch to ON. Check that all burner ports have ame.
4. Leak test all gas joints again.