PLEASE KEEP THESE INSTRUCTIONS FOR FUTURE REFERENCE N IO AT TR ty I S ra n EG ar R /w T Y c om N A ir o . R R e nv A W SHERWOOD INDUSTRIES IS AN ENVIRONMENTALLY RESPONSIBLE COMPANY. THIS MANUAL IS PRINTED ON RECYCLED PAPER. PELLET STOVE Maxx-M OWNER’S MANUAL PLEASE READ THIS ENTIRE MANUAL BEFORE INSTALLATION AND USE OF THIS PELLET-BURNING ROOM HEATER. FAILURE TO FOLLOW THESE INSTRUCTIONS COULD RESULT IN PROPERTY DAMAGE, BODILY INJURY OR EVEN DEATH.
Table of Contents Introduction........................................................................................3 Rating Label Location................................................................3 Fuel Quality...............................................................................3 Safety Warnings & Recommendations....................................................4 Operating Instructions..........................................................................
Introduction * This manual is designed for the home owner in conjunction with the technical manual. * Rating Label Location: The rating label is located on the inside of the hopper. Fuel Quality: Fuel quality is important, please read the following: Your Enviro pellet stove has been designed to burn ¼” (6mm) dia wood pellets and other organic fuels. DO NOT use this appliance as an incinerator.
Safety Warnings & Recommendations Please read this entire Owner’s Manual before installing or operating your Enviro Pellet Stove. Failure to follow these instructions may result in property damage, bodily injury or even death. Any unauthorized modification of the appliance or use of replacement parts not recommended by the manufacturer is prohibited. All national and local regulations and shall be complied with when operating this appliance. Caution: Do not connect to any air distribution duct or system.
Safety Warnings & Recommendations ELECTRICAL: The use of a surge protected power bar is recommended. The unit must be grounded. The grounded electrical cord should be connected to a standard 110-120 volts (3.6 Amps), 60 hertz electrical outlet and also must be accessible. If this power cord should become damaged, a replacement power cord must be purchased from the manufacturer or a qualified Enviro dealer.
Operating Instructions Dimensions & Specifications: 2113/16" (554mm) 1515/16" (404mm) 219/16" (548mm) 263/4" (680mm) 251/16" (637mm) 255/8" (650mm) 4113/16" (1063mm) 411/4" (1047mm) 2313/16" (605mm) Figure 1: Dimensions of Maxx-M. Table 1: Maxx-M Specifications. Description Residential Pellet Heater Fuel type 6mm (¼”) dia. Pellets - wood, corn, wheat, barley, & grass only* Voltage 110 - 120 V Current 4.
Operating Instructions Control Board Functions: 1. ON/OFF BUTTON: Used to turn the unit ON and OFF manually. 2. FUEL TYPE BUTTON: Used to switch between fuel type modes; Pellet (for all qualities of wood pellets) and Multi-fuel (for all fuels including wood pellets). When set on Multi-fuel it will run at a reduced High Feed Rate with wood pellets. NOTE: Fuel Type can only be changed when the unit is cold. PELLET PELLET 4 3.
Operating Instructions PRE-BURN CHECK: The burn pot liner holes must be clear and the liner installed properly against the ignitor tube and locked in place. Check the hopper for enough pellets to start the unit. Note: Fuel Type can only be changed when the unit is cold. The thermostat mode can be changed during normal operation. The unit has an automatic cleaning cycle;PELLET every thirty (30) minutes the agitator will turn continuously for PELLET 4 one (1) minute to help clean out the burn pot liner.
Operating Instructions Turning Your Pellet Stove Off: • MANUAL and HI / LOW mode: To turn the unit OFF, simply press the ON / OFF button. This will stop the feed of pellets. The blowers will continue to operate and cool the stove down. When cool enough, the stove will turn off. • AUTO / OFF mode: To turn the unit OFF, turn the Thermostat down or Timer off.
Routine Cleaning and Maintenance The following list of components should be inspected and maintained routinely to ensure that the appliance is operating at its optimum and giving you excellent heat value. The appliance, flue gas connector and the chimney flue require regular cleaning. Check them for blockage prior to re-lighting after a prolonged shut down period.
Routine Cleaning and Maintenance HEAT EXCHANGER TUBES (Weekly) There are two (2) sets of exchanger tube scrapers; the handles are located under the top grill (trivet). Lift the grill and move the handles all the way up and down a few times (ONLY WHEN THE UNIT IS COLD) in order to clean away any fly ash that may have collected on the heat exchanger tubes.
Routine Cleaning and Maintenance EXHAUST PASSAGES (Biannually) 1. Open the firebox door by lifting the handle. 2. Remove the burn pot assembly and clean all the parts. 3. Lubricate all screws with penetrating oil. 4. Using a ⅜” socket, remove the two (2) bolts that hold the firebox liner in place. Vacuum the firebox and firebox liner thoroughly. 5. Open the ash box door; remove the ash box and clean out the cavity. 6. Clean out the transition box to the combustion blower (located behind the ash box) 7.
Installation Data Sheet The following information must be recorded by the installer for warranty purposes and future reference.