Indoor Fireplace User Manual

Mount the two framing mount brackets on each side and secure the
replace to framing with screws or nails (refer to Figure 16). The brackets
will allow for a ” (13 mm), ” (16 mm), ” (19 mm) thick nishing
wall. The wall may be nished up to the replace facing with combustible
material.
Figure 16. Nail Tab.
Initial Installation
QUALIFIED INSTALLERS ONLY
FRAMING MOUNT BRACKETS:
CORNER INSTALLATION:
The dimensions for installing a replace in the corner of a room are given in Figures 17 and 18. Refer to
“INITIAL INSTALLATION - VENT CONFIGURATIONS AND RESTRICTOR SETTINGS” for allowable pipe lengths.
Do not interfere with the structural integrity of the walls.
Outside Wall
(Thick)
Inside
Wall
23
7
/
8
”
(605mm)
5
5
/
8
”
(143mm)
36
1
/
4
”
(920mm)
47
5
/
8
”
(1210mm)
33
3
/
4
”
(856mm)
15
1
/
2
”
(393mm)
11”
(279mm)
Figure 17. Dimensions for a corner installation, rear
vented.
15
Figure 18. Dimensions for a corner installation, top
vented.
RAISED FIREPLACES AND HEARTHS:
Figure 20. Raised Fireplace with Floor Level Hearth
Figure 19. Raised Fireplace with Raised Hearth