Specifications
11
Floor Protection
C
B
A
CLEARANCES TO COMBUSTIBLES:
Maintain these clearances to combustibles.
A) SIDE WALL TO UNIT      6 INCHES (153 mm)
B) BACK WALL TO UNIT        1 INCHES ( 25 mm)
C) ADJACENT WALL TO CORNER OF UNIT  1 INCHES ( 25 mm)
- MANTLE (HEARTH MOUNT)      8 INCHES (203 mm)
Installation
ALCOVE CLEARANCES:
This  unit  may  be  installed  in  an  alcove.  Maintain 
clearances to combustibles.
MIN. ALCOVE WIDTH 36 INCHES ( 914 mm)
MIN. ALCOVE HEIGHT 48 INCHES (1220 mm)
MIN. ALCOVE DEPTH 30 INCHES ( 762 mm)
Install vent at clearances specified by 
the vent manufacturer.
This unit can be installed on a combustible floor due to the built in pedestal hearth pad (for example 
linoleum, hardwood flooring). If combustible flooring is underneath the unit 6 inches (153 mm) on either 
side and to the front must be protected by non-combustible material. If this unit is to be installed onto 
a carpeted surface, a hearth pad must be used for stability.
3
0
"
(
75
c
m)
48"
(120cm)
36" (90cm)
Figure 13
Figure 12