Specifications

5
EF THERMO DATA:
Specifications
Necessary draught 34.8 Pa (0.348 mbar)
Water content 17.3 liters
Exhaust gas temperature at nominal heat output 230°C
Exhaust gas temperature at minimum heat output 120°C
Exhaust mass flow at nominal heat output 7.5 g/s
Exhaust mass flow at minimum heat output 8.0 g/s
Flue pipe diameter 80 mm
Nominal heat output 25 kW
Heat output range 2.5 kW - 25 kW
Combustion period at QN 12 hours
Setting range for the temperature controller 30°C - 75°C
Fuel (type, size, water content) Wood pellets, 6 mm dia. maximum, <8%wc
Hopper capacity 77.75 liters (55 Kg)
Hopper filing opening 440 mm x 320 mm
Auxiliary power requirements 800 W
Test pressure 4.5 bar
Operating pressure 0.5 bar - 2.5 bar
Maximum water pressure 3.0 bar
Maximum water temperature 90°C
Burn Rate 1.0 - 4.5 Kg/hr