Operating instructions

21
Installation
Non-combustible
floor protection.
Existing floor
(combustible)
6"
(15cm)
Rain cap
Flashing
24"
(61cm)
1"
(2.5cm)
Tee with
cleanout
Fresh air
intake
3" (7.5cm)
Clearance
Support
bracket
Type "L"
vent
Figure 27: Outside Vertical Installation.
Refer to Figures 28 and 29.
1. Install the hearth pad.
2. Lock fireplace damper in
the open position.
3. Install a positive flue
connector at the fireplace
dampers.
4. Connect a tee or a 90°
elbow to the exhaust
pipe.
5. Install flexible stainless
steel liner or listed pellet
vent to the top of the
chimney.
heaRth mount inStallation - fReeStanDing:
Floor Protection
Combustible Floor
Masonry Fireplace
Min 6"
(150 mm)
Rain Cap
Steel Plate or Flashing
Flexible or Rigid 6"
Stainless Steel Liner
10" (25.4 cm) Mantel
Minimum 8" (20 cm)
from top of stove
Damper Removed
or Fastened Open
Fresh-air intake
Clean-out tee
Fresh-air intake
should come from
chimney. If holes
already exist, fresh-
air intake can be
taken through back
of fireplace or
through ash dump.
Figure 28: Freestanding hearth mount installation.