Installation manual
19
HOW TO START AND OPERATE YOUR PELLET APPLIANCE 
1.  Check and fill hopper with 
pellets. 
2.  Make sure unit is plugged into 
a working outlet. 
3.  Switch the power “ON” by 
pushing the start up switch 
once only. 
4.  Turn knob “B” to the 12 o’clock 
position. (Lower grade pellets 
may need a higher setting on 
the feed rate). NOTE: unit will 
take longer to light if the 
hopper has been completely 
emptied. 
5.  Wait until the fire is 
established, then turn knob “B” 
to the desired heat output.  
(The stove may not be able to 
burn in the BLUE ZONE if poor 
quality wood pellets are being 
used.)
6. 
If the stove should shut off 
after 15 minutes and there is 
still a fire in the firebox – press 
the start up switch once more.  
If the fire went out, return to 
step number 2 and re-light the 
stove.
KNOB “A”:
 Fan Controller. 
By adjusting the knob you will vary the rate of airflow into the room by varying the speed of the convection blower. 
When you first start the stove it should be placed in the “OFF” position in order to heat the unit as quickly as 
possible. Once the room has come up to temperature the control may be set to a comfortable level. 
The flashing green “
Auger Light” corresponds to the timing of the auger turning. 
KNOB “B”: Dial a Fire Heat Output Knob. This knob controls the amount of heat output. The dial has a scale 
with the blue zone representing the coolest setting of the stove, and the red zone representing the hottest 
setting. The scale on knob “B” represents a range, not exact at times or fuel quantities. Wood pellets of differing 
quality may effect the performance of the stove. If the stove has trouble operating at either end of its range, turn 
the heat output knob back slightly.
TURNING YOUR PELLET STOVE OFF 
To turn your stove off, simply turn the HEAT OUTPUT knob (knob “B”) counter-clockwise until the knob clicks to 
the “OFF” position. This will stop the feed of pellets. The blowers will continue to run and cool the stove. When 
cool enough, the stove will shut down. 
Convection 
Blower Speed 
Control 
KNOB A 
Auger Light 
Start-up 
Switch 
Dial-A-Fire 
Heat Output 
Knob 
KNOB B 