DECIDING WHERE TO LOCATE YOUR PELLET APPLIANCE 
1.  Check clearances to combustibles. 
2.  Do not obtain combustion air from an attic, garage or any unventilated space. Combustion air may be 
obtained from a ventilated crawlspace. 
3.  Do not install the stove in a bedroom. 
4.  You can vent the stove through an exterior wall behind the unit or connect it to an existing masonry or 
metal chimney (must be lined if the chimney is over 6” in diameter, or over 28 sq. inches cross sectional 
area). An interior vent can be used with approved pipe passing through the ceiling and roof. 
5.  Locate the stove in a large and open room that is centrally located in the house. This will optimize heat 
circulation. 
6.  The power cord is 8 feet (2.43 m) long and may require a grounded extension cord to reach the nearest 
electrical outlet. 
FIREPLACE DIMENSIONS 
SIDE VIEW FRONT VIEW 
TOP VIEW 
UNIT DIMENSIONS 
HEIGHT: 33.056 (83.96 CM) 
WIDTH: 22.225 (56.45 CM) 
DEPTH: 21.239 (53.94 CM) 
HEARTH PAD:
WIDTH: 24.360 (61.87 CM) 
DEPTH: 27.864 (70.77 CM) 