Specifications
13
Installation
HORIZONTAL EXHAUST THROUGH WALL INSTALLATION:
Vent installation: install vent at clearances specified by the vent manufacturer.
A chimney connector shall not pass through an attic or roof space, closet or similar concealed spaces, or a floor, 
or ceiling. Where passage through a wall or partition of combustible construction is desired, the installation shall 
conform to CAN/CSA-B365 Installation Code for Solid-Fuel-Burning Appliances and Equipment. Only use venting of 
L or PL type with an inside diameter of 3 or 4 inches (7.6 or 10.1 cm).
1. Choose a location for your stove that meets 
the requirements stated in this manual and 
allows installation with the least amount of 
interference  to  house  framing,  plumbing, 
wiring, etc.
2. Install  a  non-combustible  hearth  pad 
(where necessary).
3.  Place  the  appliance  15”  (37.5  cm)  away 
from the wall. If the stove is to be set on 
a hearth pad, set the unit on it, and adjust 
the leveling legs. 
4. Locate the center of the exhaust pipe on 
the  stove.  Extend  that  line  to  the  wall. 
Once you have located the center point on 
the wall, refer to pellet vent manufacturer 
installation  instructions  for  correct  hole 
size and clearance to combustibles.
5. Install  the  wall  thimble  as  per  the 
instructions  written  on  the  thimble. 
Maintain  an  effective  vapour  barrier  in 
accordance with local building codes.
6. Install a length of 3” (75 mm) or 4” (100 
mm) vent pipe into the wall thimble. The 
pipe should install easily into the thimble.
7.  Connect  the  exhaust  vent  pipe  to  the 
exhaust  pipe  on  the  stove.  Seal  the 
connection with high temperature silicone.
8. Push  the  stove  straight  back,  leaving  a 
minimum of 4” (10 cm) clearance from the 
back of the stove to the wall.  Seal the vent 
pipe to the thimble with high temperature 
silicone.
9. The pipe must extend at least 12” (30 cm) 
away  from  the  building.  If  necessary, 
bring another length of pipe (PL type) to 
the outside of the home to connect to the 
first section. Do not forget to place high 
temperature silicone around the pipe that 
passes through the thimble.
Figure 12: Straight through wall Installation. 
Figure 13: V
enting to use with straight through wall Installation. 
Non-combustible
floor protection.
Existing floor
(combustible)
6"
(15 cm)
4"
(10 cm)
Wall
thimble
45°
elbow
12"
(30.5 cm)
Exhaust Tube
3" (75mm) or 4" (100mm) "PL" or "L" vent
Wall Thimble
45° Elbow with screen or 
Termination Cap
High Temperature RTV 
Silicone Required
Fresh Air Intake Tube










