THROUGH WALL WITH EXTERIOR BLOWER KIT INSTALLATION - HORIZONTAL TERMINATION:
Electrical Cable
90° Elbow
45°Elbow with Rodent 
screen or stainless 
steel termination hood
2ft (610mm) Riser
Pipe Adaptor
Exterior Blower 
and Housing
Wall Strap
To supply power to 
the exhaust blower
Install the  amour  coated electrical cable  from  the  exhaust blower  housing,  through the wall thimble  plate  and 
attach to the pre drilled hole in the left hand rear hopper pillar. Hook up to wires from the exhaust blower wiring 
harness. 
All electrical connections must be in accordance to local code requirements
NOTE:
Ensure that all interior vent connections are sealed by placing a small bead of high temperature silicone around 
each chimney connection.
Also  ensure  that  all  vertical  vent  sections  are  properly  supported  and  that  all  clearances  to  combustibles  are 
maintained in accordance with the vent manufacturer’s specifications.
Figure 23: Through Wall Installation with Exterior Blower Kit. 
Figure 24: Through W
all Installation with Exterior Blower Kit; Side View. 