Specifications
19
Roof Sheathing
Rain Cap
Roof Flashing
Roof Rafters
Ceiling Joists
Vent Pipe
Exterior Wall 
Sheathing
Outside Vent 
Termination
Installation
TYPICAL THROUGH WALL WITH EXTERIOR BLOWER KIT INSTALLATION - VERTICAL TERMINATION:
Figure 25: Through Wall Installation with Exterior Blower Kit; 
Vertical Termination. 
THERMOSTAT INSTALLATION:
1.  Install the wall thermostat in a location that is not to close too the unit but will effectively heat the 
desired area.
2.  The Right Cabinet Side will need to be removed to 
access the  Control Board.  Once  the  side  has  been 
removed you can remove three screws securing the 
Control Board Cover.
3.  Now that  the  board can  be  accessed,  wire  the 
Thermostat  using  to  the  Control  Board  using  an 
18  gauge,  2  connector  wire  from  the  unit  to  the 
thermostat.
Figure 26: Thermostat wire placement.
Follow  the  previous  pages  for  through  wall 
instal
lations.  Ensure  that  vent  pipe  is  properly 
secured to wall using wall straps. Maintain clearances 
to combustibles on vent pipe as well as unit.