Specifications
21
Operating Instructions
CONTROL BOARD FUNCTIONS:
1.  POWER BUTTON: This is the green button with the power symbol, it is used 
to turn the unit on and off. When the power is on and the blue LED beside the 
button will be illuminated. The LED will flash during the start-up cycle. Once start-
up cycle is complete the power LED will stay on. 
2.  AUTO BUTTON: Located below the Power button, when pressed this activates 
Auto or “Comfort” mode. LED beside button will be illuminated when active.
3.  THERMOSTAT BUTTON: Located below the Auto Button. This is  for external 
thermostat control. LED beside button will be illuminated when active.
4.  ARROW BUTTON:  The Arrow Buttons are  used to adjust  heat level  and trim 
settings.
START-UP: When the unit is turned on it will go into a start-up cycle while trying 
to light a fire. During start-up you have no control over the settings. The Power 
LED will flash until start-up is complete. You can adjust heat levels or toggle the 
different modes during start-up but these adjustments will not come into affect 
until the start-up cycle is complete.
MANUAL MODE: Once the start-up cycle is completed you will be in either Manual 
mode or Auto mode. When in Manual mode the Power LED is  illuminated and 
AUTO LED is not. Use the Arrow buttons to adjust heat level from L1-L5.
AUTO  MODE:  Press  the  Auto  button  to  activate  Auto  or  “Comfort”  mode.  When 
activated the Power and Auto LED’s will be illuminated. Use the Arrow buttons 
to adjust  from C1-C9. Each  setting  corresponds to  a  different temperature set 
point. The stove will automatically adjust to hold this temperature. As the room 
temperature gets  close to the   set point  the fire will  decrease in  size. If room 
temperature is above the set point for a certain amount of time the stove will shut 
down and go into Suspend mode.
SUSPEND MODE: Once a stove has gone into Suspend mode the fire will go out. 
This means the room has heated up beyond the Auto set point. Once temperature in the room drops below the 
Auto set point the stove start back up and run until the room gets to hot once again. When in suspend mode 
the Auto LED will flash.
THERMOSTAT MODE: This can only be used in Manual mode, and is for external thermostat control. A external 
thermostat can be wiring to the main control board. When activated the LED beside the Thermostat Button will 
be illuminated.
FEED/COMBUSTION  TRIM:  To  adjust  the  Feed  Trim  you  must  be  in  Manual  mode  heat  level  1.  Press  the 
hidden button located under the down arrow. The Display will then change from P (Program) to A (Auger) to C 
(Combustion) with a two second delay between changes. When the display shows an A use the arrows to adjust 
the feed trim. To adjust the combustion fan trim wait until the display shows C then use the arrows to adjust.
Auto
Figure 28: Circuit Board 
Control Panel Decal.
AUTOMATIC SAFETY FEATURES OF YOUR PELLET STOVE:
A. The stove will shut off when the fire goes out and the exhaust temperature drops below 120°F (49°C).
B.  The stove has a high temperature safety switch. If the temperature on the hopper reaches 200°F 
(93°C), the auger will automatically stop and the stove will shut down. The LED display will show an 
E3 error cod, see Troubleshooting section. If this happens, call your local dealer to reset the 200°F 
(93°C) high limit switch. ALSO FIND THE REASONS WHY THE UNIT OVERHEATED.
C)  The unit is equipped with a vacuum switch to monitor the venting; if it becomes blocked the vacuum 
switch will turn off the auger and there will be an E2 error code on Th eLED Display.