Routine Cleaning and Maintenance
FIREBOX PANELS
The paint on the steel firebox panels may peel. This is due to extreme conditions applied to the paint and is in no 
way covered by warranty.
AIR WASH (semi-annually)
Vacuum out the air wash passages at the top of the glass (see Figure 33). We recommend that a soft brush nozzle 
head is used on the vacuum.
EXHAUST VENT (semi-annually)
This  vent  should  cleaned  every  year  or  after  two  tons  of  pellets.  We  recommend  contacting  your  dealer  for 
professional cleaning. To clean the vent pipe, tap lightly on the pipe to dislodge any loose ash.  Open the bottom 
of the âTâ to dump the ash, then vacuum as much of the ash out of the vent pipe as possible.
BLOWER MECHANISMS (semi-annually)
Unplug the stove then open the right and left side panels to access the two blowers.  Vacuum all dust from motors. 
DO NOT lubricate the motors. Check gaskets and replace if needed.
HINGES
Check to make sure all hinges are working properly. You may use high temp anti-sieze on door hinges for smoother 
operation.
POST SEASON CLEAN-UP
Once you are finished using the pellet appliance for the season, unplug the stove for added electrical protection.  It 
is very important that the stove be thoroughly cleaned and serviced. Pellet should be regularly service for optimum 
efficiency and prolonged life.
DOOR GLASS REPLACEMENT
 Never run a stove with broken glass, new glass must be purchased and installed by a Enviro dealer. The door 
glass is made of high temperature PYROCERAM glass. To replace the glass, unscrew and remove the seven glass 
screws. Remove the glass and any broken pieces. High temperature fiberglass tape should be used around the 
glass. Replace the glass and secure using same glass retainers, make sure glass is properly seated in the cast 
door before tightening screws. The use of substitute glass materials is prohibited use only part 50-2942.