Specifications
9
Installation
Back Wall 4in (10cm)
Adjacent Wall 3in (7.5cm)
Side Wall 8in (20cm)
Hearth Pad 6in (15cm)
CLEARANCES TO COMBUSTIBLES:
IMPORTANT: The P3 must have a Hearth Pad when installing the unit on a combustible floor. The included hearth 
pad meet all the requirement of a proper hearth pad. If you do not use the included hearth pad a non combustible 
material must be placed underneath the unit and extend six inches in front of the unit measured from the door.If 
the P3 is installed on carpet the use of a solid non combustible material must be used under leveling legs.
These dimensions are minimum clearances but it 
is recommended that you ensure sufficient room 
for servicing, routine cleaning and maintenance.
Side wall to unit  8 inches  (20 cm)
Back wall to unit  4 inches  (10 cm)
Corner to unit  3 inches  (7.5 cm)
Hearth Pad  6 inches  (15 cm)
36in 
(91.5 cm)
48in 
(122 cm)
30in 
(76 cm)
The unit may be installed in an alcove if desired. 
These minimum  clearances to  combustibles must 
be maintained at all times. Be sure to leave room 
for  servicing,  routine cleaning,  and  maintenance. 
These are inside dimensions.
Minimum Alcove Width 36 inches (91.5 cm)
Minimum Alcove Height 48 inches (122 cm)
Minimum Alcove Depth 30 inches (76 cm)
ALCOVE CLEARANCES:
Figure 5: Minimum Install Clearances
Figure 6: Minimum Alcove Clearances