Operating instructions

ELECTRICAL
The ENVIRO EG 40.FS.BV. Will operate with no external power supply. These models have a Milli volt gas
control valve that uses the pilot flame to generate enough electricity to operate the main burner.
The appliance when installed must be electrically connected and grounded in accordance with local codes or in
the absence of local codes, with the current CSA C22.1 CANADIAN ELECTRICAL CODE Part 1, SAFETY
STANDARDS FOR ELECTRICAL INSTALLATIONS, or THE NATIONAL ELECTRICAL CODE ANSI / NFPA 70 in
the USA.
NOTE:
Operation of the fan increases the
efficiency and the heat output of the
appliance.
The thermostat connects to the two
purple wires in the harness
Control panel light uses a 7W bulb
max.
WARNING: ELECTRICAL
GROUNDING INSTRUCTIONS.
This appliance is equipped with a three-
prong (grounding) plug for your
protection against shock hazard and
should be plugged into a properly
grounded three-prong receptacle.
DO NOT cut or remove the grounding
prong from the plug.
INSTALLING REMOTE THERMOSTAT OR WALL SWITCH
RECOMMENDED WIRE SIZE for thermostat installation: 18 Gauge, 2 wire solid core, Low Voltage wire. (Bell wire)
1. Install the 18 Gauge wire supplied to the two terminals on the thermostat or remote wall switch.
2. Connect the other end of the wire to the gas valve using the two outside terminals on the front of the gas valve.
Use the terminals marked (TP/TH and TH).
RECOMMENDED MAXIMUM LEAD LENGTH (TWO WIRE)
WHEN USING WALL THERMOSTAT
WIRE SIZE
MAXIMUM LENGTH
14 GAUGE 100 Feet (30.5m)
16 GAUGE 64 Feet (19.5m)
18 GAUGE 40 Feet (12.2m)
20 GAUGE 18 Feet (5.5m)
CAUTION
Label all wires
prior to
disconnection
when servicing
controls. Wiring
errors can cause
improper and
dangerous
operation. Verify
proper operation
after servicing.
13