SHERWOOD INDUSTRIES IS AN ENVIRONMENTALLY RESPONSIBLE COMPANY THIS MANUAL IS PRINTED ON RECYCLED PAPER EG 40 B Vented OWNERS MANUAL By SHERWOOD INDUSTRIES LTD. WHAT TO DO IF YOU SMELL GAS • Open windows • Do not try to light any appliance. • Do not touch any electrical switch; do not use any phone in your building. • Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's instructions. • If you cannot reach your gas supplier, call the fire department.
SAFETY PRECAUTIONS FOR SAFE INSTALLATION AND OPERATION OF YOUR "ENVIROGAS" STOVE, PLEASE, CAREFULLY READ THE FOLLOWING INFORMATION: • GENERAL • Installation and repair should be done by a qualified service person. The appliance should be inspected before use and at once least annually by a qualified service person. More frequent cleaning may be required due to excessive lint from carpeting, bedding material, etc.
TABLE OF CONTENTS Safety Precautions Code Approvals 2 3 Deciding where to locate your stove Venting Installation of Log Sets and Embers Operating Instructions Maintenance and Technical Trouble Shooting Gas Line Connection Electrical Parts and Accessories Fuel Type Conversion Warranty Parts List Exploded views Installation Data Sheet 4 6 8 9 10 11 12 13 14 15 16 17 18-19 20 CODE APPROVALS • This Vented appliance draws all of its combustion air from the dwelling and must be vented using listed B or L ven
DECIDING WHERE TO LOCATE YOUR STOVE DIMENSIONS: Front Width: 25"/ 63 cm Rear Width: 25"/ 63 cm Height: 29"/ 74 cm* Depth 21"/ 53 cm ( *not including vent coupling ) Shipping Weight: 256 lbs/116 kg CLEARANCES: A. Side wall to stove B. Rear wall to stove C. Combustible to stove Top D. Floor to stove E. Corner clearance F. Alcove depth FIG. 1 12"/ 30cm 4"/ 10cm 36”/ 91cm 0"/ 0cm 2"/ 5cm 48"/ 122cm Maintain sufficient clearances for service and maintenance FIG.
VENT TERMINAL CLEARANCES H= *Not to be installed above a meter/regulator assembly within 3 feet (90cm) horizontally from the center-line of the regulator I= Clearance to service regulator vent outlet [*6 feet (1.8m) minimum] J= Clearance to non-mechanical air supply inlet to building or the combustion air inlet to any other appliance [12 inches (30cm) minimum] K= Clearance to a mechanical air supply inlet [*6 feet (1.
VENTING This model must have a vent opening in the rear of the unit. Confirm this and also check that the label on the right side panel door states "Vented Room Heater". WARNING: THIS APPLIANCE HAS BEEN DESIGNED TO OPERATE BY DRAWING COMBUSTION AIR AND DILUTION AIR FROM THE ROOM. THE DRAFT HOOD LOCATED IN THE SAME ATMOSPHERIC PRESSURE ZONE AS THE COMBUSTION AIR INLET TO THE APPLIANCE. IT IS ALSO DESIGNED TO DRAW ROOM AIR FOR PROPER HEAT CIRCULATION FROM THE REAR OF THE UNIT.
A. USING AN EXISTING CHIMNEY • • • • • Measure the height of the chimney beforehand and purchase the appropriate kit. Never attempt to over stretch a flexible liner to accommodate the height of the chimney. Any flue damper must be removed or locked permanently in the open position. The chimney must be clean, in good working order and constructed out of non-combustible materials. Make sure that all chimney clean-outs are tightly fitting and will not permit air to leak into the chimney.
INSTALLATION OF LOG SET and EMBERS INSTALLING THE GLOWING EMBERS A bag of ceramic fiber embers is provided for use on the front burner ember tray. CAUTION: Use only the type of ember material supplied with this appliance. Due to the irregular size of the ember material there may be more than required. Use only a single layer. Do not pile embers. The use of other foreign materials on the burners may create dangerous conditions.
OPERATING INSTRUCTIONS FOR YOUR SAFETY READ BEFORE OPERATING WARNING: IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY, A FIRE OR EXPLOSION MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY OR LOSS OF LIFE. A) This appliance is equipped with a pilot, which must • If you cannot reach your gas supplier, call the be lit by hand by following these instructions exactly. fire department.
MAINTENANCE AND TECHNICAL To Replace: • open door fully • Lift door vertically so that hinge pins lift out of hinge receivers. • Return the door assembly to dealer. Door and glass assembly must be replaced as a complete unit by your ENVIROGAS Dealer. No substitute materials are allowed. Annually check to ensure that your Vent system is clear. Periodically check the pilot and burner. Check to see that all the burner ports are clean and clear. Check the pilot head for blockage.
TROUBLE SHOOTING Problem Spark will not light the pilot after repeated pressing of spark igniter Pilot will not remain lit Burners will not remain lit Flame lifting Glass fogs up Blue flames Flames are burning “dirty” or Sooting Flame goes out / comes on frequently during a short period of time Possible Cause Defective piezo igniter Solution Check connections to igniter -If igniter connections are good but there is no spark-replace igniter Broken spark electrode -Check for broken ceramic insulation re
GAS LINE CONNECTION ORIFICE SIZES, PRESSURE AND BTU’S FRONT BURNER REAR BURNER Manifold pressure. Min. Manifold pressure. Supply Pressure. Min. Supply pressure. Max. BTUH Input. Min. BTUH Input. Output fan off Output fan on NATURAL GAS #48 (1.93mm) #41 (2.49 mm) 3.8” wc (.95 kPa) 1.1” wc (.27 kPa) 7.0” wc (1.74 kPa) 5” wc (1.25 kPa) 38,000 Btu/h (11.1 kW) 20,000 Btu/h (5.9 kW) 27,800 Btu/h (8.14 kW) 29,400 Btu/h (8.6 kW) PROPANE GAS #55 (1.32mm) #54 (1.40 mm) 11” wc (2.74 kPa) 2.7” wc (.67 kPa) 12” wc (2.
ELECTRICAL The ENVIROGAS EG 40.FS.BV. will operate with no external power supply. These models have a Milli volt gas control which uses the pilot flame to generate enough electricity to operate the main burner. The appliance when installed, must be electrically connected and grounded in accordance with local codes or in the absence of local codes, with the current CSA C22.1 CANADIAN ELECTRICAL CODE.
PARTS AND ACCESSORIES Service Parts available from your local Envirogas Dealer Convection Blower Light Bulb Holder Light Switch (momentary) Fan Controller Log Set (with Embers) Thermocouple Embers Thermopile Door Gasket Convection Fan Sensor 120 F (49C) Burner Control Assembly Natural Gas Pilot Assembly Propane Pilot Assembly Door Bolt Relief Door Gasket Regulating Valve Piezo Igniter Burner Switch B-vent Spill switch 220° Orifice Blank Accessories Gold trim Package Low Voltage Thermostat REMOVING or LUB
• • • • There is a separate air shutter for each burner. Remove one screw from the cover plate located below the ash shelf. Loosen the other screw (do not remove) swing the cover plate out of the way and tighten screw down to hold it in place. With along screwdriver rotate spring clips to open or close the shutter to the desired setting. The burner flame should be a bright yellow/orange when hot.
WARRANTY Sherwood Industries Ltd. offers a *Lifetime Warranty on this gas product. The lifetime warranty covers the appliance for a period of seven years from the date of installation. This warranty applies only to the original owner in the original location Covered under the lifetime warranty are Cabinet Sides, Tops, Pedestals, Surround Panels and Chassis and Heat Exchanger.
PARTS LIST EG40-081 EG40-084 EG40-086 EG40-087 EG40-088 EG40-091 EG40-093 EG40-098 EG40-099 EG40-120 EG40-122 EG40-123 EG40-129 EG40-135 EG40-200 EG40-202 EG40-205 UPPER GOLD BARS (SET of 2) FS LOWER GOLD BAR FS SIDE PANEL BV STOVE TOP FIREBOX BAFFLE STOVE TOP BAFFLE IEC POWER CORD OUTLET FRONT VENTURI REAR VENTURI FS BURNER GASKET FS PILOT TUBING AND FITTINGS WINDOW CHANNEL TAPE 72” STEEL BRICK LINER FS PEDESTAL DOOR LP to NG CONVERSION KIT NG to LP CONVERSION KIT 3 Pc.
FRONT BURNER REAR BURNER EG40-089 EG40-090 PAINTED DOOR ASSEMBLY WITH GLASS (A + B) FULLY ASSEMBLED PILOT EG40-073 EC-015 NG, 016 LP GOLD DOOR ASSEMBLY WITH GLASS (A + B) THERMOPILE REAR LOG SUPPORTS EC-012 EG40-075 THERMOCOUPLE EC-009 PILOT ORIFICE GLASS RETAINER EC-019 NG, 020 LP SPARK ELECTRODE EC-011 REAR VENTURI DOOR LATCH BOLT DOOR LATCH STRIP HINGE SET OF 2 EC-059 EG40-302 EG40-099 GAS TRAY TOP AND SIDES FRONT VENTURI GLASS EXTRUSIONS EG40-098 CONTROL PANEL ORIFICE BLANK FS
FS STOVE TOP (BV or DV) EG40-087 1 X 1 SIDE CABINET HINGE FLUE PIPE EC-054 120° F (49° C) FAN TEMP SENSOR EC-001 CONVECTION BLOWER FS SIDE PANEL CABINET EG40-035 EG40-049 FS FAN MOUNT EG40-304 CONVECTION AIR DEFLECTORS EG40-033 220° F (104° C) SPILL SWITCH EC-002 FS UPPER BAR SET EG40-081 FS SIDE PANEL CABINET EG40-049 FS LOWER BAR EG40-084 FS PEDESTAL WIRING PLATE FS ASH SILL EG40-213 FS PEDESTAL BOX COVER EG40-307 FS PEDESTAL DOOR EG40-135 EG 40 EMBLEM EG 40 FREESTANDING BODY (chass
INSTALLATION DATA SHEET The following information must be recorded by the installer for warranty purposes and future reference.