Initial Installation
QUALIFIED INSTALLERS ONLY
ELECTRICAL REQUIREMENTS:
The ENVIRO EG28 will operate without electrical power. This model has a millivolt gas control, which
uses the pilot ame to generate enough electricity to operate the main burners. The appliance is
equipped with a blower and must be electrically connected and grounded in accordance with local codes
or in the absence of local codes, with the current CSA
C22.1 CANADIAN ELECTRICAL CODE Part 1, SAFETY
STANDARDS FOR ELECTRICAL INSTALLATIONS, OR
THE NATIONAL ELECTRICAL CODE ANSI / NFPA 70
in the U.S.
WARNING: Electrical grounding instructions. This
appliance is equipped with a three-prong (grounding)
plug for your protection against shock hazard, and
must be plugged directly into a properly grounded
three-prong outlet.
DO NOT cut or remove the grounding prong from this
plug.
CAUTION: Label all wires prior to disconnection when
servicing controls. Wiring errors can cause improper
and dangerous operation. Verify proper operation
after servicing.
NOTE:
• Operation of the fan increases the efciency and the
heat output of the appliance.
• The thermostat connects to the two purple wires in
the harness
• Control panel light uses a 7 Watt max. bulb
Figure 37: EG28 DV Wiring Diagram.
Table 7. Recommended Thermostat
Wire Size.
Wire Size Max. Length
14 gauge 100 ft (30.48 m)
16 gauge 60 ft (18.29 m)
18 gauge 40 ft (12.00 m)
20 gauge 25 ft (7.62 m)
22 gauge 18 ft (5.49 m)
C
O
O
L
/
H
E
A
T
P
R
O
G
R
A
M
D
O
W
N
U
P
7
0
°
F
7
0
°
F
O
N
O
F
F
Figure 38: Wiring of a Thermostat
• If the unit is installed in a Mobile
Home it must be connected to a
grounding rod.
• If the unit is installed in a Mobile
Home it must be bolted securely
to the oor.