Owner`s manual
7
Figure 2: Circuit Board Control 
Panel Decal.
automatic Safety featuReS of youR PeLLet Stove:
A. The  stove  will  shut  off  when  the  fire  goes  out  and  the  exhaust  temperature  drops  below  120°F 
(49°C).
B.  The stove has a high temperature safety switch. If the temperature on the hopper reaches 200°F 
(93°C), the auger will automatically stop and the stove will shut down when the exhaust temperature 
cools #4 light flashes. Dealer will have to reset the sensor. If this happens, call your local dealer to reset 
the 200°F (93°C) high limit switch. ALSO FIND THE REASONS WHY THE UNIT OVERHEATED.
C)  The unit is equipped with a vacuum switch to monitor the venting; if it becomes blocked the vacuum 
switch will turn off the auger and the #2 light on the control board will flash.
oPeRating youR PeLLet Stove:
PRE-BURN INSTRUCTIONS: The burn pot liner holes must be clear and the liner installed properly 
against the ignitor tube for proper operation. Check the hopper for enough pellets to start the unit.  
DO NOT OPERATE THE UNIT WITH THE DOOR OR ASH PAN OPEN. 
Note: The thermostat mode can be changed during normal operation.
Operating Instructions
contRoL boaRD functionS:
1.  AUGER LIGHT: This green light will flash in conjunction with the auger pulse.
2.  MODE LIGHT: Responsible for signaling the state of the control board. When the light is flashing the 
stove is in an automatic start mode or the thermostat has control of the unit. When the light is solid, 
the Heat Level Setting can be altered.
3.  THERMOSTAT SWITCH: Used to set the unit’s controls to one of three mode settings; manual, 
high/low, or auto/off.
4.  FEED RATE TRIM BUTTON: Used to change the feed rate trims in ¼ second increments for all 
feed settings. When this button is pressed, all the light will light up 
on  the  Heat  Output  Indicator  except  for  the  one  that  shows  the 
current setting; the default setting is the number 4 light. To adjust 
the setting hold the Feed Rate Trim button down and press the Heat 
Level up or down buttons to adjust the setting.
5.  COMBUSTION  BLOWER  TRIM  BUTTON:  Used  to  change  the 
Combustion Blower trims in 5 volt increments for all feed settings 
until it reaches line voltage. When this button is pressed, all the light 
will light up on the Heat Output Indicator except for the one that 
shows the current setting; the default setting is the number 2 light. 
To adjust the setting hold the Combustion Blower Trim button down 
and press the Heat Level up or down buttons to adjust the setting.
6.  ON/OFF BUTTON: Used to turn the unit ON and OFF.
7.  HEAT  LEVEL  ADJUSTMENT  BUTTONS:  When  pressed,  will 
change the heat level setting of the unit up or down.
8.  HEAT OUTPUT INDICATOR: Shows the present heat output 
setting.