Owner`s manual
veRticaL RiSe With hoRizontaL teRmination inStaLLation (RecommenDeD) - fReeStanDing:
A  45°  elbow  with  a  rodent  screen  may  be  used 
in  place  of  the  termination  cap  (or  stainless  steel 
termination hood).
Recommended vent size for vertical installation:
Under 15ft:  3” Vent
Over 15ft:  4” Vent
thRough concRete WaLL With veRticaL RiSe inStaLLationS - fReeStanDing:
A 45° elbow with a rodent screen may be used 
in place of the termination cap (or stainless steel 
termination hood).
This  is  the  recommended  installation  to  use  if 
there is a concrete or retaining wall in line with 
exhaust vent on pellet stove. 
The termination must be 12 inches (30 cm) from 
the outside wall and 12 inches (30 cm) above the 
ground. 
Recommended vent size for vertical installation:
Under 15ft:  3” Vent
Over 15ft:  4” Vent
Figure 16: Vertical rise with Horizontal Termination. 
Figure 15: Through Wall with Horizontal Termination. 