SHERWOOD INDUSTRIES IS AN ENVIRONMENTALLY RESPONSIBLE COMPANY. THIS MANUAL IS PRINTED ON RECYCLED PAPER. PLEASE KEEP THESE INSTRUCTIONS FOR FUTURE REFERENCE PELLET STOVE Empress-A-FS TECHNICAL MANUAL Contact your building or fire officials about restrictions and installation inspection requirements in your area. PLEASE READ THIS ENTIRE MANUAL BEFORE INSTALLATION AND USE OF THIS PELLET-BURNING ROOM HEATER. FAILURE TO FOLLOW THESE INSTRUCTIONS COULD RESULT IN PROPERTY DAMAGE, BODILY INJURY OR EVEN DEATH.
Table of Contents Introduction...................................................................................................................................3 Rating Label Location...........................................................................................................3 Important Safety Data.........................................................................................................3 Safety Warnings And Recommendations........................................................
Introduction * This manual is designed for the technician in conjunction with the owner’s manual. * IMPORTANT SAFETY DATA: Please read this entire Owner’s Manual before installing or operating this ENVIRO Pellet Stove. Failure to follow these instructions may result in property damage, bodily injury or even death. Contact your local building or fire official to obtain a permit and any information on installation restrictions and inspection requirements for your area.
Introduction ELECTRICAL: The use of a surge protected power bar is recommended. The unit must be grounded. The grounded electrical cord should be connected to a standard 120 volts, 60 hertz electrical outlet and also must be accessible. If this power cord should become damaged, a replacement power cord must be purchased from the manufacturer or a qualified ENVIRO dealer. Be careful that the electrical cord is not trapped under the appliance and that it is clear of any hot surfaces or sharp edges.
J F M A M J J A S O N D 2005 2006 DATE OF MANUFACTURE / DATE DE FABRICATION: 2007 Pour l'usage avec les combustibles sous forme de boulets uniquement. Fonctionner seulement avec la vue de porte et la porte d'enlèvement de cendre ont fermé. Seulement remplacer le verre avec le verre de ceramique. Les composants ont exigé pour l'installation : 3 pouce (75 mm) ou 4 pouce (100 mm) a énuméré le conduit de PL complète avec les composants.
Installation DECIDING WHERE TO LOCATE YOUR PELLET APPLIANCE: 1. Do not install the stove in a bedroom or room where people sleep in. 2. Locate the stove in a large and open room that is centrally located in the house. This will optimize heat circulation. 3. Check clearances to combustibles and for the least amount of interference to house framing, plumbing, wiring, etc. 4. You can vent the stove with approved pipe through an exterior wall behind the unit or pass it through the ceiling and roof.
Installation DIMENSIONS: 153/4" (400mm) 153/8" (390mm) 253/4" (653mm) 247/16" (621mm) 273/8" (695mm) 243/16" (614mm) Figure 3: Empress Freestanding Dimensions. CLEARANCES TO COMBUSTIBLES: These dimensions are minimum clearances but it is recommended that you ensure sufficient room for serving, routine cleaning and maintenance. Adjacent 3" wall (76mm) 3" (76mm) Side wall This pellet stove requires floor protection.
Installation ALCOVE CLEARANCES: Minimum Width 48" (1219mm) This unit may be installed in an alcove. Maintain the clearances to combustibles shown in Figure 4. Install vent at clearances specified by the vent manufacturer. Minimum Height 48" (1219mm) Maximum Depth 30" (760mm) Figure 5: Alcove Clearances. MOBILE HOME INSTALLATION: ● Secure the heater to the floor using the holes in the leg of the appliance (normally used for the leveling legs).
Installation EXHAUST AND FRESH AIR INTAKE LOCATIONS: INSTALL VENT AT CLEARANCES SPECIFIED BY THE VENTING MANUFACTURER 9 9/16" (243mm) 7 7/16" (189mm) 4 3/8" (112mm) 3 1/16" (77mm) Figure 7: Inlet and Outlet Location. EXHAUST Base of unit to center of flue Center of unit to center of flue 9 9/16” (243 mm) 3 1/16” (77 mm) FRESH AIR INTAKE.
Installation VENT TERMINATION REQUIREMENTS: IT IS RECOMMENDED THAT YOUR PELLET STOVE BE INSTALLED BY AN AUTHORIZED DEALER/INSTALLER. Table 1: Use in conjunction with Figure 9 for allowable exterior vent termination locations. Letter Minimum Clearance A 24 in (61 cm) B 48 in (122 cm) Beside/below any door or window that may be opened. (18” (46 cm) if outside fresh air installed.) C 12 in (30 cm) Above any door or window that may be opened. (9” (23 cm) if outside fresh air installed.
Installation CORNER THROUGH WALL INSTALLATION: Fresh Air Intake 3" (7.5 cm) Wall thimble manufactured by pellet vent manufacturer. 3" (7.5 cm) Figure 10: Corner Installation. HORIZONTAL EXHAUST THROUGH WALL INSTALLATION: Vent installation: install vent at clearances specified by the vent manufacturer. A chimney connector shall not pass through an attic or roof space, closet or similar concealed spaces, or a floor, or ceiling.
Installation 10. The pipe must extend at least 12” (30 cm) away from the building. If necessary, bring another length of pipe (PL type) to the outside of the home to connect to the first section. Do not forget to place high temperature silicone around the pipe that passes through the thimble. Exhaust 3" (75mm) or 4" (100mm) "PL" or "L" Vent Wall Thimble 45o Elbow with Screen or Termination Cap Fresh Air Intake High Temperature RTV 11.
Installation VERTICAL RISE WITH HORIZONTAL TERMINATION INSTALLATION (RECOMMENDED): Termination cap 90°elbow Wall framing A 45° elbow with a screen may be used in place of the termination cap (or stainless steel termination hood). Vertical section of vent pipe Wall strap Horizontal frame for thimble Clean out tee ������ ������� Wall thimble Figure 13: Through Wall with Horizontal Termination.
Installation INSIDE VERTICAL INSTALLATIONS: 1. Choose a stove location that is ideal. See the section “INSTALLATION - DECIDING WHERE TO LOCATE YOUR PELLET APPLIANCE.” 2. Place the unit on the hearth pad (if installed on a carpeted surface) and space the unit in a manner so when the pellet vent is installed vertically, it will be 3” (76 mm) away from a combustible wall. 3. Locate the center of the fresh air intake pipe on the unit.
Installation OUTSIDE VERTICAL INSTALLATIONS: To accomplish a outside vertical pipe installation, follow steps 1 through 5 in the “INSIDE VERTICAL INSTALLATIONS” section and then finish it by performing the following (refer to Figure 15). 1. Install a tee with clean out on the outside of the house. 2. Install PL vent upward from the tee. Make sure that you install support brackets to keep the vent straight and secure. 3. Install ceiling thimble and secure the flashing as you go through the roof. 4.
Installation HEARTH MOUNT INSTALLATION: Damper Removed or Fastened Open Mantel Minimum 8" (20 cm) from top of stove Clean-out Fresh-air intake should com from chimney. If holes already exist fresh-air intake can be taken through back of the fireplace or through the ash dump. Min 6" (150 mm) Floor Protection Masonry Fireplace Combustible Floor Figure 17: Hearth Mount - Side View.
Installation INSTALLATION WITH EXTERIOR MOUNTED EXHAUST BLOWER: The Empress can be equipped with an externally mounted exhaust blower (PART #20-070). This optional kit will include all components necessary to install the exhaust blower on any external vertical wall surface. Choose a location for your stove that meets the requirements stated in this manual and allows installation with the least amount of interference to house framing, plumbing, wiring, etc.
Installation 9. Connect the wires in the stove. Re-install the left side access cover to the stove and the back grill on the exterior vent housing. 10. Set the Slider Damper as described in the INSTALLATION - SLIDER/DAMPER SETTING“ section. NOTE: Ensure that all vent connections are installed by placing three (3) screws evenly spaced and a small bead of high temperature silicone at each chimney connection.
Installation THROUGH WALL VERTICAL INSTALLATION WITH EXHAUST BLOWER: Refer to INSTALLATION - INSTALLATION WITH EXTERIOR MOUNTED EXHAUST BLOWER and INSTALLATION - OUTSIDE VERTICAL INSTALLATIONS. Ensure that vent pipe is properly secured to wall using wall straps. Maintain clearances to combustibles on vent pipe as well as unit.
Installation THERMOSTAT INSTALLATION: 1. Install the wall thermostat in a location that is not to close too the unit but will effectively heat the desired area. 2. Install a 12 or 24 Volt Thermostat using an 18 x 2 gauge wire from the unit to the thermostat. Remove jumper wire and install thermostat wires here. Figure 23: Thermostat wire placement. If the unit has been placed in the HI / LOW mode, the unit will be taken to a low or idle setting when the thermostat is not calling for heat.
Installation The low burn collar must be set on a hot stove; run the unit on low for 30 minutes, and place a Magnahelic Pressure Gauge in the firebox (test port is located in the center of the stove just below the door opening). Set the slider at 0.11” W.C. (30 Pa) for the firebox vacuum and lock the set collar in place (refer to Figure 23). Some fuels may require higher or lower settings. The combustion exhaust blower is a variable speed blower controlled by the heat output setting.
Troubleshooting DO NOT: ● Service the stove with wet hands. The stove is an electrical appliance, which may pose a shock hazard if handled improperly. Only qualified technicians should deal with possible internal electrical failures. ● Do not remove from the firebox any screws without penetrating oil lubrication. ● Hold the ON / OFF BUTTON down. This is a momentary contact switch and can be damaged if held down too long. WHAT TO DO IF: 1. The stove will not start. 2. The stove will not operate when hot. 3.
Troubleshooting üCheck vacuum levels in the exhaust channel by bypassing the vacuum switch, then remove the vacuum hose from vacuum switch. Check exhaust vacuum readings by placing the open end of the vacuum hose on a Magnahelic Gauge (readings must be above 0.18” to 0.20” W.C. (44.8 to 49.8 Pa) on low fire). If the motor fails to reach a 0.10” W.C. readings, then replace the combustion blower.
Troubleshooting Auger light flashes but auger motor does not turn at all. üIf the auger gear box does not turn but the motor’s armature does try to spin then the auger is jammed. – Try to break apart jam by poking at the jam through the drop tube. If this fails then empty the hopper and remove the auger cover **remember to re-seal the cover after installation** üCheck the fuse on the circuit board. 6. The 200 °F ( 93 °C) high limit temperature sensor has tripped.
Wiring Diagram Armor Cable Supplied Optional Exterior Exhaust Blower Grey Grey Black Combustion Blower Vacuum Switch White White Blue Brown Exhaust Temperature Sensor Power Cord Brown Ground 115V Black 220V Brown Thermostat 5 Amp Fuse Black White Orange Orange Purple Blue Yellow Red Grey Grey Brown Brown Red Red Connect Thermostat Here 115V White 220V Blue Hot Red White Black Black Common Ignitor Purple White Yellow White Orange Orange Convection Blower Auger Motor High Limit Temperat
Parts List - Components Reference Number 1 2 3 4 5 5 6 7 8 9 10 11 12 13 14 26 Description 120 °F (49 °C) Ceramic Fan Temperature Sensor Domestic Power Cord - 115V Auger Motor - 115V High Limit Temp Sensor 200 °F (93 °C) Manual Reset Vacuum Switch - 115V Silicone Hose Aluminum Hose Barb Slider Damper Rod with Knob Knob 1” Round Pellet Stove Cleaning Brush External Exhaust Kit (3” pipe) Door Screen Heat Exchanger Rod Brick Panel Retainers (set of 2) Front Casting Mounts - Right & Left Door Knob - Brushe
Parts List - Components Reference Number 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 Description 5⁄8“ ID Auger Collar with Screw Empress Domestic Owner’s Manual - 115V Empress Domestic Technical Manual - 115V Auger - 115 V Ignitor tube with mounting flange Cast Brick Panel Set Auger Plate with bushing Ash Pan With Painted Knob Hopper Lid Back grill Access Panel - Left Access Panel - Right Stainless Steel Burn Pot Liner - Low Ash Ignition Burn Pot Slider Damper Plate Exhaust Starter Tube 3” x 21⁄2”
Parts List - Cast Reference Number 32 32 32 32 32 32 32 32 33 33 33 33 33 33 33 33 34 34 34 34 34 34 34 34 35 35 35 35 35 28 Description Cast Cast Cast Cast Cast Cast Cast Cast Cast Cast Cast Cast Cast Cast Cast Cast Cast Cast Cast Cast Cast Cast Cast Cast Cast Cast Cast Cast Cast Ash Shelf - Painted Ash Shelf - Antique White Ash Shelf - Diamond Black Ash Shelf - Inferno Red Ash Shelf - Pearl Grey Ash Shelf - Wedgewood Blue Ash Shelf - Westport Green Ash Shelf - Antique Chestnut Front Complete (Doors & A
Parts List - Cast Reference Number 35 35 35 36 36 36 36 36 36 36 36 37 37 37 37 37 37 37 37 Description Cast Side Right - Wedgewood Blue Cast Side Right - Westport Green Cast Side Right - Antique Chestnut Cast Grate - Painted Cast Grate - Antique White Cast Grate - Diamond Black Cast Grate - Inferno Red Cast Grate - Pearl Grey Cast Grate - Wedgewood Blue Cast Grate - Westport Green Cast Grate - Antique Chestnut Cast Top Only (No Grate) - Painted Cast Top Only (No Grate) - Antique White Cast Top Only (No Gr
Parts Diagram - Components EMPRESS - Components (115V) October 2006 �� �� � �� �� �� � � �� � �� 30 �
Parts Diagram - Steel & Cast �� �� EMPRESS - Steel & Cast (115V) October 2006 �� �� �� �� � � � �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� � 31
Warranty Sherwood Industries Ltd. is the manufacturer of the Enviro line of heating products. At Sherwood Industries, our commitment to the highest level of quality and customer service is the most important thing we do. Each Enviro stove is built on a tradition of using only the finest materials and is backed by our Exclusive Lifetime Limited Warranty to the original purchaser. With Enviro, you’re not just buying a stove, you’re buying a company with years of unequalled performance and quality.
Warranty Exclusions and Limitations: 1. This Warranty does not cover tarnish, discoloration or wear on the plating or paint. 2. This Warranty excludes wear and tear or breakage caused by cleaning, moving or service on log set. 3. A qualified installer must install this stove or fireplace. This Limited Warranty covers defects in materials and workmanship only if the product has been installed in accordance with local building and fire codes; in their absence, refer to the owner’s manual.
Warranty 17. Damage to plated surfaces caused by fingerprints, scratches, melted items, or other external scores and residues left on the plated surfaces from the use of abrasive cleaners or polishes is not covered in this warranty. 18. The Limited Warranty does not cover tarnish, discoloration or wear on the plated surfaces. 19. The paint on the Metal Brick Liner may peel. This is due to the extreme conditions applied to the paint during normal usage. It is not a flaw and is not covered under warranty. 20.
Installation Data Sheet The following information must be recorded by the installer for warranty purposes and future reference.