Owner`s manual
8
Operating Instructions
contRoL boaRD functions:
ON/OFF
HEAT LEVEL
AUTO/OFF
HIGH/LOW
MANUAL
AUGER
C-11767
POWER
A
B
1
2
4
3
5
6
7
ON/OFF
HEAT LEVEL
AUTO/OFF
HIGH/LOW
MANUAL
AUGER
C-11767
POWER
A
B
1. AUGER LIGHT: This green light will flash in
conjunction with the auger pulse.
2. POWER LIGHT: Responsible for signaling the
state of the control board. When the light is
flashing the stove is in an automatic start mode
or the thermostat has control of the unit. When
the light is solid, the Heat Level Setting can be
altered.
3. THERMOSTAT SWITCH: Used to set the unit’s
controls to one of three mode settings; manual,
high/low, or auto/off.
4. A & B BUTTONS: To be used by Pellet Stove
Technicians only, not to be used by home owner.
5. ON/OFF BUTTON: Used to turn the unit ON and
OFF.
6. HEAT LEVEL ADJUSTMENT BUTTONS: When
pressed, will change the heat level setting of the
unit up or down.
7. HEAT OUTPUT INDICATOR: Shows the present
heat output setting.
Figure 2: Circuit Board Control Panel Decal.
automatic safety featuRes of youR PeLLet stove:
A. The stove will shut off when the fire goes out and the exhaust temperature drops below 120°F (49°C).
B. The stove has a high temperature safety switch. If the temperature on the hopper reaches 200°F
(93°C), the auger will automatically stop and the stove will shut down when the exhaust temperature
cools #4 light flashes. Dealer will have to reset the sensor. If this happens, call your local dealer to reset
the 200°F (93°C) high limit switch. ALSO FIND THE REASONS WHY THE UNIT OVERHEATED.
C) The unit is equipped with a vacuum switch to monitor the venting; if it becomes blocked the vacuum
switch will turn off the auger and the #2 light on the control board will flash.
oPeRating youR PeLLet stove:
PRE-BURN INSTRUCTIONS: The burn pot liner holes must be clear and the liner installed properly
against the ignitor tube for proper operation. Check the hopper for enough pellets to start the unit.
DO NOT OPERATE THE UNIT WITH THE DOOR OR ASH PAN OPEN.
Note: The thermostat mode can be changed during normal operation.