Owner`s manual

13
Installation
FUEL CONVERSION:
Warning: A qualied service technician, in accordance with the manufacturer’s instructions
as well as all applicable authority having jurisdiction, shall install this conversion kit.
If the information in these instructions is not followed exactly, a re, explosion or
CO poisoning, may result. The qualied service agency is responsible for the proper
installation of this kit. The installation is not proper or complete until the operation
of the converted appliance is checked as specied in the owner’s conversion kit.
Please read and follow these instructions. Also please read the instruction guide lines provided by S.I.T on how to
remove and install the HI-LOW regulator.
STEP 1. Carefully inspect all parts supplied with this conversion kit.
STEP 2. Shut the gas off and disconnect the main gas line from the unit.
STEP 3. Open the door by unscrewing the two
5
/16” bolts on the top corners of the doorframe. Lift the door off
the mount at the bottom of the doorframe. Remove the burner tray top from the appliance.
STEP 4. Change the regulator on the front of the gas valve. (Follow the instructions provided by S.I.T)
STEP 5. To change the pilot orice, simply pull the pilot hood straight up to access the pilot injector. Using a
5
/32
Allen key remove the pilot injector and replace with new pilot injector supplied in the conversion kit.
STEP 6. Install the new pilot injector supplied with this conversion kit. Simply screw the new injector inside the
pilot hood and reinstall pilot hood by placing hood on the assembly, lining up the key-way and snap into
place.
STEP 7. Remove the main burner orice with a ” deep socket.
STEP 8. Install the new orice supplied. Be sure to put a bead of pipe thread sealant or approved Teon tape on
the orice before installing into the burner assembly.
STEP 9. Re-install burner tray, log set and door.
STEP 10. Reconnect the gas line to the unit. Do a leak check using a soap and water solution or an approved
method on the gas supply line.
STEP 11. Re-light the appliance to insure proper operation and proper ame appearance. Be sure to adjust the
venturi setting to achieve an efcient ame in the replace.
STEP 12. MAKE SURE that the sticker provided by S.I.T is installed to signify that this valve has been converted to
a different type of fuel. Also make sure that the rating plate has a conversion label to show that this unit
has been converted to a different fuel type.
A VISUAL CHECK OF THE REGULATOR KNOB IS NECESSARY TO DETERMINE WHETHER OR NOT THE REGULATOR
IS THE CORRECT PART. A 50% TURN DOWN REGULATOR WILL HAVE ONLY ONE CORNER ON THE KNOB.
1 50% turn down HI-LOW Regulator with 3 T-20 Torx screws
1 pilot injector
1 Main orice
NATURAL GAS PROPANE
Pilot Orice. .51mm .35mm
Burner Orice. #38 dms #52 dms
Venturi Settings
1
/16” min
3
/16” min
Conversion instructions.
Labels to show conversion.